45376001TH Rev.1 79 /Oki Data CONFIDENTIAL 4. Component replacement4.2.10 Stay-R(1) Remove the right side cover. (See section 4.2.3)(2) Remove the Scanner.(3) Remove the soft-absorber ① and cover side(R-Inner) ② .(4) Remove the seven screws (silver,No:42920406) ③ and remove the Stay-R ④ .Note! When assemble the scanner, assemble the soft-absorber correct positionand close the scanner.(Frame and soft-absorber break may occur)4.2.11 Plate-Board-R Assy/Guide-Cable Power Low(1) Remove the right side cover. (See section 4.2.3)(2) Remove the stay-R Assy. (See section 4.2.10)(3) Remove the rear cover. (See section 4.2.7)(4) Remove the plate shield and take the CU/PU PCB out. (See section 4.2.9)(5) Remove the eight screws (silver, No:42920406) ① ,remove the two screws(black,No:42932706) ② and remove the Plate-Board-R-Assy ③ .(6) Remove the Guide-Cable Power Low ④ .