45376001TH Rev.1 97 /Oki Data CONFIDENTIAL 4. Component replacement4.2.34 Guide-Assy-Retard(1) Remove the eight claws and remove the Guide-Retard(sub) ① .(2) Remove the Cover-Retard(ADF) ② .(3) Remove the Frame-Assy Retard ③ and remove the spring Retard ④ .(4) Remove the Lever-Hopping ⑤ and the spring-Hopping ⑥ .(5) Remove the Photo-coupler ⑦ and remove the cable (conn cord AMP3P-JST4P) ⑧ .ClawClawClawClawClaw4.2.35 Flatbed-Unit(1) Remove the five screws (black, No:42932706) ① and remove the cover-Bottom ② .(2) Remove the screw (silver, No:42920406) ③ and remove the plate-stopper(OP) ④ .(3) Remove the two screws (black, No:PB4083-5670P013) ⑤ and remove thecover-OP ⑥ .(4) Remove the screw (black, No:42932708) ⑦ and remove the Handle-scanner(S) ⑧ .(5) Rotate the OP-panel-unit ⑨ 90 degrees.(6) Remove the two screws (silver, No:42920406) ⑩ .(7) Remove the screw (silver, No:42920406) ⑪ and remove the clamp-cable ⑫ andremove the OP-panel-unit ⑨ .Attention of assembly for direction of plate-stopper(OP)(for finisher model) (for without finisher model)