11788-6-2 BATTERY SETTING1The ____ in the Adjustable Range column indicates the presetmode.Items/Data SavedAdjustableRange RemarksPRO14 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:13.7:15.0When MANUAL is selected in the abovemenu, set the NEAR END voltage in 0.1 Vsteps.– C U F –TRIM14 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:13.6:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –HYTRON50 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:13.1:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –HYTRON100 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:13.2:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –HYTRON120 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:13.1:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –Items/Data SavedAdjustableRange RemarksDIONIC90 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:13.6:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –DIONIC160 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:13.3:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –HP-90L _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:12.4:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –BP-H120 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:11.5:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –NP-L50 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:13.0:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –ᤨࠫ