118The remaining battery capacity for digital batteries is displayedas % inside the viewfinder (PRO14/TRIM14/HYTRON50/HYTRON100/HYTRON120/DIONIC90/DIONIC160/NP-L50/ENDURA50/ENDURA80).The BATT NEAR END alarm, however, is triggered according tothe setting on the screen, regardless ofthe % indication.8-6-3 BATTERY SETTING2Items/Data SavedAdjustableRange RemarksENDURA50 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:13.1:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –ENDURA80 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:13.5:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –BP-L60/90 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.AUTOMANUALSelect auto or manual to set the NEAR ENDvoltage.AUTO: Set voltage automatically.MANUAL : Set voltage manually.11.0:11.2:15.0When MANUAL is selected in the menuabove, set the NEAR END voltage in 0.1 Vsteps.– C U F –Items/Data SavedAdjustableRange RemarksNiCd14 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.NEAR END 11.0:13.6:15.0Set the NEAR END voltage in 0.1 V steps.END 11.0:13.2:15.0When MANUAL is selected in the menuabove, set the END voltage in 0.1 V steps.– C U F –NiCd13 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.NEAR END 11.0:12.7:15.0Set the NEAR END voltage in 0.1 V steps.END 11.0:12.2:15.0When MANUAL is selected in the menuabove, set the END voltage in 0.1 V steps.– C U F –NiCd12 _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.NEAR END 11.0:11.5:15.0Set the NEAR END voltage in 0.1 V steps.END 11.0:11.2:15.0When MANUAL is selected in the menuabove, set the END voltage in 0.1 V steps.– C U F –TYPE A _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.FULL 12.0:15.0:17.0Set the voltage to display the FULLindication in 0.1 V steps.NEAR END 11.0:13.6:15.0Set the NEAR END voltage in 0.1 V steps.END 11.0:13.2:15.0When MANUAL is selected in the menuabove, set the END voltage in 0.1 V steps.– C U F –TYPE B _•Enable selection under BATTERY SELECT._:Enable selection.• :Disable selection.FULL 12.0:13.5:17.0Set the voltage to display the FULLindication in 0.1 V steps.NEAR END 11.0:11.8:15.0Set the NEAR END voltage in 0.1 V steps.END 11.0:11.1:15.0When MANUAL is selected in the menuabove, set the END voltage in 0.1 V steps.– C U F –ᤨࠫ