74Setup Software (continued)The screens of Windows 10 are used in the explanations in this manual.If you are using an operating system other than Windows 10, some of the items displayed on the screens may differ.Settings for connecting with the remote cameraszz When connecting with the remote camera, select [MAINTENANCE] > [RP SETTING] of the unit and register the ID and password in advance.(page 53)zz When using Setup Software, select [MAINTENANCE] > [RP SETTING] > [PC_TOOL LINK] of the unit and set [ENABLE]. (page 53)zz If you forget the ID or password, execute initialization on this unit with [MAINTENANCE] > [RP INITIALIZE] > [INIT ALL], then reset the ID andpassword.Note that when this operation is performed, all the setting values on this unit are returned to the factory defaults.Displaying the [Setting] tab12 312 13 1714 15 164 5 9 10 116 7 81 IPSet the IP address for the AW‑RP60 to be connected.2 IDSet the ID registered in the AW‑RP60 to be connected.3 PASSWORDSet the password registered in the AW‑RP60 to be connected. The password is displayed as “*”.When operating the buttons for each menu item (tab), the account information (1 to 3) above is used for the authentication by AW‑RP60.4 CAMERA GROUPThe camera group number is displayed.5 CAMERA NOThe camera number is displayed.6 CNTRL TYPESelect the connection type.Click on the right and select the connection type from amongst [Serial], [Network], and [NoAsign].Serial : Serial connectionNetwork : IP connectionNoAsign : No settingCamera numbers [CAM1] to [CAM5] can be selected for [Serial].7 CAMERA NAMEDisplays the camera name set on the remote camera.zz These are displayed when they are acquired with [AUTO IP SET] on the main unit or with [AUTO IP CAM ASSIGN] on this software.