Model Heating capacities are based on conditions below.CS-A24BB4PHeating capacity7.1 kW1 phase, 50Hz, 230VIndoor temperature 20°C D.B.Outdoor temperature 7°C D.B. 6°C W.B.Standard air volume 17m3/minInlet Air Outdoor Temperature (°C W.B.)External StaticPressure (Pa) AirVolume (m3/min)Entering AirDry Bulb (°C)-6 0 6 12H.C. H.C. H.C. H.C.15 5.18 6.21 7.46 8.6617 20 4.90 5.86 7.10 8.5225 4.62 5.54 6.75 8.17Inlet Air Outdoor Temperature (°C W.B.)External StaticPressure (Pa) AirVolume (m3/min)Entering AirDry Bulb (°C)-6 0 6 12IPT IPT IPT IPT15 1.74 1.99 2.37 2.7917 20 1.84 2.12 2.49 2.8925 1.94 2.24 2.61 2.95Model Heating capacities are based on conditions below.CS-A28BB4PHeating capacity8.0 kW1 phase, 50Hz, 230VIndoor temperature 20°C D.B.Outdoor temperature 7°C D.B. 6°C W.B.Standard air volume 18m3/minInlet Air Outdoor Temperature (°C W.B.)External StaticPressure (Pa) AirVolume (m3/min)Entering AirDry Bulb (°C)-6 0 6 12H.C. H.C. H.C. H.C.15 5.84 7.00 8.40 9.7618 20 5.52 6.60 8.00 9.6025 5.20 6.24 7.60 9.20Inlet Air Outdoor Temperature (°C W.B.)External StaticPressure (Pa) AirVolume (m3/min)Entering AirDry Bulb (°C)-6 0 6 12IPT IPT IPT IPT15 1.92 2.19 2.60 3.0718 20 2.03 2.33 2.74 3.1825 2.14 2.47 2.88 3.22H.C. = Heating CapacityIPT = Power Consumption15 CAPACITY AND POWER CONSUMPTION15.1. HEATING PERFORMANCE60CASSETTE TYPE