27Indoor Model CS-RZ50WKRWPOS (EAN) 5025232913152Outdoor Model CU-RZ50WKRPOS (EAN) 5025232913190Weight Net (I/D O/D) kg (lb) 8 (18) / 36 (79)Gross (I/D O/D) kg (lb) 9 (20) / 39 (86)Stacking No. (CS / CU / CZ) 12 / 6 / -PipingPipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2)Standard Length m (ft) 5.0 (16.4 )Length Range (min - max) m (ft) 3 (9.8) ~ 30 (98.4)I/D & O/D Height Different m (ft) 15 (49.2)Additional Gas Amount g/m (oz/ft) 15 (0.2)Length for Additional Gas m (ft) 10 (32.8)Drain Hose Inner Diameter mm 16.7Length mm 650Indoor HeatExchangerFin Material Aluminium (Pre coat)Fin Type Slit FinRow x Stage x FPI 2 x 15 x 21Size ( W x H x L) mm 580 x 315 x 25.4Outdoor HeatExchangerFin Material Aluminium (Blue Coat)Fin Type Corrugated FinRow x Stage x FPI 2 x 28 x 17Size ( W x H x L) mm 36.4 x 588 x 856.3:827.7Air Filter Material PolypropeleneType One-touchPower Supply OutdoorPower Supply Cord NILThermostat Electronic ControlProtection Device Electronic ControlDry Bulb Wet BulbIndoor Operation RangeCooling Maximum °C (°F) 32 (89.6) 23 (73.4)Minimum °C (°F) 16 (60.8) 11 (51.8)Heating Maximum °C (°F) 30 (86.0) -Minimum °C (°F) 16 (60.8) -Outdoor Operation RangeCooling Maximum °C (°F) 46 (114.8) 26 (78.8)Minimum °C (°F) -10 (14.0) -Heating Maximum °C (°F) 24 (75.2) 18 (64.4)Minimum °C (°F) -15 (5.0) -1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor airtemperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).3. Heating low temperature capacity, Input Power and COP measured at 230V, indoor temperature 20°C, outdoor 2/1°C.4. Heating extreme low temperature capacity, Input Power and COP measured at 230V, indoor temperature 20°C, outdoor -7/-8°C.5. TCSPF and HSPF only indicate the value of Residential Mixed Zone.6. Sound pressure level specification is measured according to JIS C9612 [<70 dB(A)].7. Specifications are subjected to change without prior notice for further improvement.