266APR 2002Edition 2.0DP-1510P/1810P/1810F/2010E51 Photo Mode Image Density Image density adjustment for Photo mode.(-) : Darker.(+) : Lighter.-99 - +9952 Not Used53 CCD Read Timing Adjustment of CCD read position.(+) : More delay.(-) : Less delay.-44 - +440.2mm54-68 Not Used69 Stamp Position Adjustment Adjustment of verification stamp position.(+) : More delay.(-) : Less delay.-7 - +70.5mm70-78 Not Used79 MTF Adjustment Adjustment of MTF.(+) : Darken edge.(-) : Lighten edge.-127 - +12780-82 Not Used83 Laser Unit Image Side(Sheet Bypass)Laser write start position adjustment (sideto side adjustment).(+) : More delay.(-) : Less delay.-8 - +70.5mm84 Laser Unit Image Side (1st Tray)85 Laser Unit Image Side (2nd Tray)86 Laser Unit Image Side (3rd Tray)87 Laser Unit Image Side (4th Tray)88 Not Used89 Laser Unit Image Side(Auto. Duplex Unit)Laser write start position adjustment (sideto side adjustment).(+) : More delay.(-) : Less delay.-8 - +70.5mm90 ADF Image Read Start Adjustment of ADF horizontal image readstart position.(+) : More delay.(-) : Less delay.-50 - +90.2mm91 ADF Original Lead EdgeRegistrationAdjustment of original detection timing.(+) : More delay.(-) : Less delay.-99 - +990.2mm92 Not Used93 ADF Original Trail Edge Adjustment of original trail edge detection.(+) : More delay.(-) : Less delay.-127 - 1270.2mm94 ADF Magnification Ratio(Top Feed)Adjustment of ratio when the scan is made.(+) : Increase.(-) : Decrease.-9 - +90.1%95-98 Not Used99 All F6 Parameters Initialize Initialize All F6 Parameters -F6 ModeNo. Item Function Setting