- 18 -ENSetting the tool to configurationmode1. Turn off the control panel.• If the control panel is on, removeand then reinsert the battery pack.2. Engage the switch while pushing thebutton and then release both thebutton and the switch.• After all the LED lamps have turnedoff, the control panel will flash andchange to configuration mode.[Fig.20]NOTE:• Tools ship from the factory set to “F”mode (torque control function off).• The control panel will turn off if thetool is not operated for a period of 5minutes.Configuring the torque clutch setting[Fig.21]1. Press the and buttons to selectthe clutch setting that is appropriatefor the work being performed.[EYFLA4, EYFLA5, EYFLA6, EYFMA1]3…281F30 229As the buttonis pressedAs the buttonis pressed• “F” indicates that the torque controlfunction is off.• You can select from 30 torque clutchsettings (1 to 30).[EYFLA7, EYFLA8, EYFLA9, EYFMA2]3…381F40 239As the buttonis pressedAs the buttonis pressed• “F” indicates that the torque controlfunction is off.• You can select from 40 torque clutchsettings (1 to 40).• Use figures from the TighteningTorque Chart to guide your selectionof torque clutch setting. (See the fol-lowing tightening torque chart)2. Press the OK button to accept theselected torque clutch setting.• The control panel will stop flashingand light up.CAUTION:• You must press the OK button in orderfor the selected setting to take effect.• Be sure to verify the new value afterchanging the setting.Tightening Torque Chart (for ReferenceUse)The values illustrated on this chart weremeasured under the conditions describedbelow and are provided for reference pur-poses. Actual tightening torque varies withambient conditions (the particular bolt beingtightened, hardware being used, method ofholding the bolt in place, etc.).[EYFLA4, EYFLA5, EYFLA6, EYFMA1][Fig.22][EYFLA7, EYFLA8, EYFLA9, EYFMA2][Fig.23]Measurement conditions• Temperature: Room temperature(20°C/68°F)Setting the snug point detection level[Fig.24]1. Press the A button.• The snug point detection level settingvalue will be displayed.[Fig.25]2. Press the and buttons to set thebest snug point detection level for thework you’re performing.3. Press the OK button to accept thenumber of torque stages and thesnug point detection level.The tool’s panel will flash and then lightup continuously.