Panasonic FX-305 Instruction Manual
PART DESCRIPTION6MODE keyJog switchDigital display (Red)MODE indicator /PRO (Yellow)MODE indicator / L/D ON (Yellow)Output 1 operation indicator(Orange)MODE indicator / RUN (Green)MODE indicator / ADJ (Yellow)MODE indicator / TEACH (Yellow)MODE indicator / TIMER (Yellow)Output 2 operationindicator (Orange)OPERATION PROCEDURE7٨ When the power supply is switched on, communication self-check is car-ried out and normal condition is displayed [MODE indicator / RUN(green)] lights up and the digital display shows the incident light intensity.TEACHING MODE8In case of 2-level teachingԙ Press Jog switch in the object present condition. If theteaching is accepted, the read incident light intensity blinks inthe digital display. (Note 1)Ԛ Press Jog switch in the object absent condition. (Note 1)PressPressPressԘ Press MODE key to light up MODE indicator / TEACH (yellow).Set to either Output 1 ' ' or Output 2 ' '.Turn Jog switch: SelectPress Jog switch: Confirmedԛ The threshold value is set at the mid-value between ԙ and Ԛ.In case stable sensing is possible: '䇭䇭䇭䇭' is displayed.In case stable sensing is not possible: '䇭䇭䇭䇭' is displayed.Note: In case of using the fibers, if Jog switch is pressed in the object absent condition at ԙ and Ԛ,the sensitivity is set to the maximum.PressPressԘ Press MODE key to light up MODE indicator / TEACH (yellow).Set to either Output 1 ' ' or Output 2 ' '.Turn Jog switch: SelectPress Jog switch: Confirmedԛ In case stable sensing is possible: '䇭 䇭 䇭 䇭' is displayed.In case stable sensing is not possible: '䇭 䇭 䇭 䇭' is displayed.ԙ Press Jog switch continuously for 0.5 sec. or more with theobject moving on the assembly line.Ԛ ' ' is displayed on the digital display. Release the jogswitch when the object has passed.In case of full-auto teachingPressPressԘ Press MODE key to light up MODE indicator / TEACH (yellow).Set to Output 1 ' '.Turn Jog switch: SelectPress Jog switch: Confirmedԛ In case stable sensing is possible: '䇭 䇭 䇭 䇭' is displayed.In case stable sensing is not possible: '䇭 䇭 䇭 䇭' is displayed.٨ This is the method of setting the threshold range by 1-level teaching. The shiftvalue can be set as desired.In case of window comparator mode / 1-level teaching1_SL P-1 2_SLSet asdesiredSet asdesiredԙ The current teaching method is displayed for 0.5 sec.Ԛ Press Jog switch in the object present condition. If theteaching is accepted, the read incident light intensity blinks inthe digital display.Ԝ A value deducted the shift value (100) from the incident lightintensity becomes the threshold value (1_SL), which isdisplayed. (Note 1) (Note 2)ԝ A value added the shift value (100) to the incident lightintensity becomes the threshold value (2_SL), which isdisplayed. (Note 1) (Note 2)The shift value 100 digits is the initial value. The shift value can be changed in PRO mode.Furthermore, 'digit' or 'percent' can be selected. For the setting method refer to ' PROMODEPRO6 mode setting'.In case the set value exceeds the max. (min.) sensitivity, the set value is fixed at max.(min.) sensitivity.Notes: 1)2)13In case of teaching in the window comparator mode, set the detailed settings inPRO6 beforehand. For the settings, refer to ' PRO MODEPRO6 mode setting'.13In case of limit teachingPressPressԘ Press MODE key to light up MODE indicator / TEACH (yellow).Set to either Output 1 ' ' or Output 2 ' '.Turn Jog switch: SelectPress Jog switch: Confirmedԙ Press Jog switch in the object absent condition. If theteaching is accepted, the read incident light intensity blinks inthe digital display.Ԛ Turn Jog switch to the '+' side or the '-' side.If Jog switch is turned to '+' side, the threshold value level is shift edto a value approx. 15% higher (lower sensitivity) than that set at Ԙ.If Jog switch is turned to '-' side, the threshold value level is shiftedto a value approx. 15% lower (higher sensitivity) than that set at Ԙԛ In case stable sensing is possible: '䇭 䇭 䇭 䇭' is displayed.In case stable sensing is not possible: '䇭 䇭 䇭 䇭' is displayed.The approx. 15% amount of shift is the initial value. The amount of shift can be changed in thePRO mode from approx. 0 to 80% (5% step). For the setting method refer to ' PRO MODEPRO1 mode setting'.Note:13The 0-ADJ setting function in this product was removed from production starting May, 2005.*1:*2:*3:*4:*5:When Jog switch is pressed, the setting is confirmed.When MODE key is pressed for 2 sec., or more, the sensor returns to the 'RUN' mode.Cancellation is possible by pressing MODE key during setting.When Jog switch is turned in the 'RUN' mode, the current threshold value is displayed.And then, the current incident light intensity display appears again automatically.If the jog switch and MODE key are pressed for more than 2 sec. at the same time in 'RUN'mode condition, the key operations are locked, and only the threshold value confirmationfunction or the adjust function (valid only when the adjust lock function is canceled) is valid.To cancel the lock function, press both the keys for more than 2 sec. once again.MODE keyPress Press Turn'+' side '-' sideJog switch٨ PRO modeThe items that can be set in output 1 and output 2 respectively are only the following.The items other than those are common.ԘThreshold value ԙOutput operation ԚTimer operation and Timer priod ԛDetection mode٨ NAVI modeThis indicates normal sensing operation.RunRUNRefer to ' TEACHING MODE'.8Sets the threshold value by, '2-level teaching' or'limit teaching', 'full-auto teaching', 'Max. sensitivityteaching', 'Window comparator1-level / 2-level /3-level teaching'.TeachingTEACHRefer to ' THRESHOLD VALUE FINEADJUSTMENT MODE'.9Allows fine adjustment of the threshold value.AdjustADJRefer to ' OUTPUT OPERATIONSETTING MODE'.11Sets output operation either Light-ON, or Dark-ON.L-ON/D-ONL/D ONRefer to ' TIMER OPERATIONSETTING MODE'.12Configures operation of the timer.TimerTIMERRefer to ' PRO MODE'.13Allows various detailed settings to be configured, suchas optical communications, save/load and other settings.ProPROPress٨ To PRO modePressPressPressPressPressPressRefer to ' PROMODE PRO1mode setting'.13TurnResponse time change function ''Timer setting function ''Hysteresis function ''Shift function ''Emitting power selection function ''PRO1Refer to ' PROMODE PRO2mode setting'.13PRO2TurnRefer to ' PROMODE PRO3mode setting'.13Refer to ' PROMODE PRO5mode setting'.13Refer to ' PROMODE PRO4mode setting'.13Setting condition copyfunction ''Remote data bank loadsetting function ''Remote data bank savesetting function ''Communication lock function ''Back-up function ''PRO4TurnTurnTurnTurnPRO3Data bank load setting function ''Data bank save setting function ''Refer to ' PROMODE PRO6mode setting'.13PRO5Code setting function ''Adjust lock setting function ''Setting reset function ''Interference prevention function''PRO6Output setting function '', ''ECO mode setting function ''Digital display setting function ''Digital display inversion function ''Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com |
Related manuals for Panasonic FX-305
Panasonic FX-301-HS Instruction Manual
Panasonic FX-502 Instruction Manual
Panasonic FX-502 Instruction Manual
Panasonic FX-501 Instruction Manual
Panasonic FX-411 Instruction Manual
Panasonic FZ-11 Instruction Manual
Panasonic FX-505P-C2 Instruction Manual
Panasonic MJE-FX501 Instruction Manual
Panasonic FX-311 Series Instruction Manual
Panasonic GA-311 Instruction Manual
manualsdatabase
Your AI-powered manual search engine