15 ERROR INDICATION● In case of errors, attempt the following measures.Errorindication Description RemedyEEPROM is broken or reached the end of itsworking life. Please contact our office.EEPROM writing errorLoad of the sensing output 1 is short-circuitedcausing an over-current to flow. Turn OFF the power and check the load.Load of the sensing output 2 is short-circuitedcausing an over-current to flow.Communication error when the amplifiers aremounted in cascade.Verify that there is no loose or clearance betweenamplifiers.Communication error between the upper com-munication unit and amplifiers.Verify that there is no loose or clearance betweenthe upper communication unit and amplifiers.16 SPECIFICATIONSType Series connection typeNPN output PNP outputModel No. FX-502 FX-502PSupply voltage 12 to 24V DC % Ripple P-P10% or lessPower consumption(Note 1)Normal operation: 960mW or less (current consumption 40mA or less at 24V supply voltage)Eco mode: 680mW or less (current consumption 28mA or less at 24V supply voltage)Sensing output(Sensing output 1 / 2)NPN open-collector transistor• Maximum sink current: 50mA (Note 1)• Applied voltage: 30V DC or less(Between sensing output and 0V)• Residual voltage: 2V or less (Note 2)[At 50mA (Note 1) sink current]PNP open-collector transistor• Maximum source current: 50mA (Note 1)• Applied voltage: 30V DC or less(Between sensing output and +V )• Residual voltage: 2V or less (Note 2)[At 50mA (Note 1) source current]Output operation Switchable either Light-ON or Dark-ONShort-circuit protection IncorporatedResponse time H-SP: 25μs or less, FAST: 60μs or less, STD: 250μs or less, LONG: 2ms or less,U-LG: 4ms or less, HYPR: 24ms or less, SelectableExternal input• Signal conditionHigh: +8V to +V DC or OpenLow: 0 to +1.2V DC (at 0.5mA source current)• Input impedance: Approx. 10kΩ• Signal conditionHigh: +4V to +V DC (at 3mA sink current)Low: 0 to +0.6V DC or Open• Input impedance: Approx. 10kΩProtection IP40 (IEC)Ambient temperature-10 to +55°C (If 4 to 7 units are mounted in cascade: -10 to +50°C or if 8 to 12 units aremounted in cascade: -10 to +45°C) (No dew condensation or icing allowed)Storage: -20 to +70°CAmbient humidity 35 to 85% RH, Storage: 35 to 85% RHMaterial Enclosure: Polycarbonate, Switch: TPEE, Protective cover: PolycarbonateWeight (Main body only) Approx. 15gAccessory FX-MB1 (Amplifier protection seal): 1 set.Notes: 1) 50mA max. if 5 or more series connection types are connected together.2) In case of using the quick-connection cable (cable length 5m) (optional).3) Cables are not accessories. Be sure to use cables in table below.CableCable length 1m Cable length 2m Cable length 5mMain cable Sub cable Main cable Sub cable Main cable Sub cableFX-502□ CN-74-C1 CN-72-C1 CN-74-C2 CN-72-C2 CN-74-C5 CN-72-C516 CAUTIONS● This product has been developed / produced for industrial use only.● Make sure that the power supply is OFF while adding or removing the amplifiers.● Take care that if a voltage exceeding the rated range is applied, or if an ACpower supply is directly connected, the product may get burnt or be damaged.● Take care that short-circuit of the load or wrong wiring may burn or damagethe product.● Do not run the wires together with high-voltage lines or power lines, or putthem in the same raceway. This can cause malfunction due to induction.● The specification may not be satisfied in a strong magnetic field.● Verify that the supply voltage variation is within the rating.● If power is supplied from a commercial switching regulator, ensure that the frameground (F.G.) terminal of the power supply is connected to an actual ground.● In case noise generating equipment (switching regulator, inverter motor, etc.)is used in the vicinity of this product, connect the frame ground (F.G.) terminalof the equipment to an actual ground.● The ultra long distance (U-LG, HYPR) mode is more likely to be affected byextraneous noise since the sensitivity of that is higher than the other modes.Make sure to check the environment before use.● Do not use during the initial transient time (H-SP, FAST, STD: 0.5 sec., LONG,U-LG, HYPR: 1 sec.) after the power supply is switched ON.● Be sure to using the quick connection cable (optional) as cable. When you ex-tend the cable, be sure to use cables which have 0.3mm 2 or more of conductorcross-section area. Extension up to total 100m is possible. However, in orderto reduce noise, make the wiring as short as possible.● Make sure that stress by forcible bend or pulling is not applied to the sensorcable joint and fiber cable.● This product is suitable for indoor use only.● Avoid dust, dirt, and steam.● Take care that the product does not come in contact with oil, grease, organicsolvents such as thinner, etc., strong acid or alkaline.● This product cannot be used in an environment containing inflammable or ex-plosive gasses.● Never disassemble or modify the product.● This product adopts EEPROM. Settings cannot be done 100 thousand timesor more because of the EEPROM’s lifetime.13 OPTICAL COMMUNICATION● When the setting of data bank loading / saving, copy setting, or copy actionsetting is conducted via optical communications, cascade the sub amplifiersright side to the main amplifier as follows.However, in case using data bank loading / saving, use FX-502□ or FX-505□-C2as main amplifier.● If an amplifier is under any of the following conditions, the setting of data bankloading / saving, or copy setting cannot be carried out.• Copy lock setting is set to copy lock ON “ .”• Digital display is blinking• External input setting of main amplifier is set to “ .” (Only data-bank loading / saving)● When communication protocol of asub amplifier is set to communicationemission halt “ ” the set-ting of data bank loading / saving, orcopy setting cannot be carried out tosub amplifiers subsequent to the men-tioned amplifier.● Make sure to mount closely like fol-lows since interference preventionfunction is conducted by optical com-munication.● When this product and other products (e.g. fiber sensor amplifiers, pressuresensor controllers, etc.) are connected together in cascade, install those prod-ucts so that they are in order of Group A, B, D and C as shown in the right fig-ure. This product is included in Group D.Group Model No.A FX-301□ (Conventional version unit)FX-301B□/G□/H□, LS-401□B FX-301□ (Modified version unit)FX-305□, FX-301□-C1C LS-403□, DPS seriesD FX-500 series● As for the products that are located between different groups, affix the ampli-fier protection seal FX-MB1 (optional) on the communication window of eachcorresponding product.● Within each group, identical models should be connected in a lump.● In case conducting copy setting of this device and other FX-500 series togeth-er, functions which are incorporated in this device will be copied but functionswhich are not incorporated in this device will not be copied.13 INTERFERENCE PREVENTION FUNCTION● This device incorporates an interference prevention function by setting differ-ent emitting frequencies from an interference prevention function by opticalcommunication.● For Interference prevention function setting procedure, refer to “PRO MODEOPERATION MANUAL.”● Possible number of amplifiers for interference prevention function is differentas shown in table below.Response timeInterferenceprevention function settingH-SP FAST STD LONG U-LG HYPR0 2 4 8 8 12● In case putting in more amplifiers than limit of interference prevention function,put the amplifier protection seal to amplifier which is adjacent of end of an ampli-fier that the interference function is valid or set OFF in communication protocolsetting of the end of amplifier that the interference prevention function is valid.Example: Putting in 12 of this device and set STD of response time setting.• Possible number of interference prevention is 4.Put the amplifier protection seals 4th and 5th amplifiers and between 8thand 9th amplifiers or change the communication protocol setting of 4th and8th to OFF since interference prevention works from 1st to 4th, from 5th to8th and 9th to 12th.● In case mounting more amplifiers whose response time setting are different,put protection seal between amplifiers that have different response time settingor set communication protocol setting of the upper amplifier to OFF.● For communication protocol setting procedure, refer to “PRO MODE OPERA-TION MANUAL.”GroupAGroupBGroupDGroupCCommunication directionCommunication directionInterferencepreventionpossiblerangePut a protection seal between4th and 5th amplifier.Or set communication protocolsetting in 4th to OFF.Put a protection seal between8th and 9th amplifier.Or set communication protocolsetting in 8th to OFF.Interference preventionpossible rangeInterference preventionpossible rangeMain amplifier Sub amplifiersCommunication directionOverseas Sales Division (Head Office)2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, JapanPhone: +81-568-33-7861 FAX: +81-568-33-8591Europe Headquarter: Panasonic Electric Works Europe AGRudolf-Diesel-Ring 2, D-83607 Holzkirchen, GermanyPhone: +49-8024-648-0US Headquarter: Panasonic Electric Works Corporation of America629 Central Avenue New Providence, New Jersey 07974 USAPhone: +1-908-464-3550PRINTED IN CHINA © Panasonic Electric Works SUNX Co., Ltd. 2010http://panasonic-electric-works.net/sunx