HOWLER_START_TIMEValue Format IntegerDescription Specifies the length of time, in seconds, that busy or reorder tones playuntil they switch to howler tones.Value Range 0–120 (0: Disable)Default Value 30Web User Interface Reference Start Time (Page 118)BELL_CORE_PATTERN1_TIMINGValue Format Comma-separated IntegerDescription Specifies the cadence, in milliseconds, of pattern ID 1, described in theLSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,using 2 whole numbers separated by a comma.Value Range 0–5000 (0: Infinite time)Default Value 2000,4000BELL_CORE_PATTERN2_TIMINGValue Format Comma-separated IntegerDescription Specifies the cadence, in milliseconds, of pattern ID 2, described in theLSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,using 4 whole numbers separated by commas.Value Range 0–5000 (0: Infinite time)Default Value 800,400,800,4000BELL_CORE_PATTERN3_TIMINGValue Format Comma-separated IntegerDescription Specifies the cadence, in milliseconds, of pattern ID 3, described in theLSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,using 6 whole numbers separated by commas.Value Range 0–5000 (0: Infinite time)Default Value 400,200,400,200,800,4000BELL_CORE_PATTERN4_TIMINGValue Format Comma-separated Integer168 Administrator Guide Document Version 2010-084.5.2 Tone Settings