352-5-5 Wiring for Manual Reset (Interlock is Valid)(Wiring Example of the Control Category 4)This is the general configuration using one set of the emitter and receiver facing each other.The control output (OSSD 1 / 2) turns OFF if the light is blocked.Interlock function Valid (Manual reset)External device monitor function ValidAuxiliary output Can be usedThe device output is selected depending on the connecting state of the output polarity setting wire(shield). Incorrect wiring may cause the lockout state.* SymbolsSwitch S1Vs to Vs - 2.5V (sink current 5mA or less): Emission halt (Note 1), Open: EmissionK1, K2: External device (Forced guided relay or magnetic contactor)Notes: 1) Vs is the applying supply voltage.2) The circuit diagram shown above is for 12-core cable to be used. For 8-core cable, red, yellow, gray, gray /black, sky-blue / white, sky-blue / black, there is no lead wire.3) For resetting, refer to “3-2 Interlock Function.”+ 24V DC±10%-K1K2Load*S1K1 K2EmitterReceiverGray cableGray cablewith black line(Shield) Output polarity setting wire(Blue) 0V(Brown) +V(Pale purple) Interlock setting input(Gray) Interference prevention +(Gray / Black) Interference prevention -(Red) Muting lamp output(Yellow) Override input(Yellow-green) External device monitor input(Brown) +V(Shield) Output polarity setting wire(Sky-bule / White) Muting input A(Sky-bule / Black) Muting input B(Gray / Black) Interference prevention -(Gray) Interference prevention +(Pink) Emission halt input / Reset input(Yellow-green / Black) Auxiliary output(Blue) 0V(Orange) Synchronization +(Orange / Black) Synchronization -(Orange) Synchronization +(Orange / Black) Synchronization -(Black) Control output 1 (OSSD 1)(White) Control output 2 (OSSD 2)