53Interlock function Invalid (Auto-reset)External device monitor function ValidAuxiliary output Can be usedThe device output is selected depending on the connecting state of the output polarity setting wire(shield). Incorrect wiring may cause the lockout state.* SymbolsSwitch S10 to +1.5V (source current 5mA or less): Emission, Open: Emission haltSwitch S2The muting input, the override input0 to +1.5V (source current 5mA or less): Valid, Open: InvalidK1, K2: External device ( Forced guided relay or magnetic contactor)Note: The incandescent lamp with 3 to 10W shall be connected to the muting lamp output. If the muting lamp is notconnected, the muting function does not operate.+ 24V DC±10%-K1K2*S1(Note 1)*S2Load*S2*S2K1 K2ReceiverEmitterGray cableGray cablewith black line(Gray) Interference prevention +(Gray / Black) Interference prevention -(Red) Muting lamp output(Yellow) Override input(Brown) +V(Yellow-green) External device monitor input(Brown) +V(Shield) Output polarity setting wire(Blue) 0V(Sky-bule / White) Muting input A(Sky-bule / Black) Muting input B(Gray) Interference prevention +(Gray / Black) Interference prevention -(Pale purple) Interlock setting input(Pink) Emission halt input / Reset input(Yellow-green / Black) Auxiliary output(Shield) Output polarity setting wire(Orange) Synchronization +(Orange / Black) Synchronization -(Orange) Synchronization +(Orange / Black) Synchronization -(Blue) 0V(Black) Control output 1 (OSSD 1)(White) Control output 2 (OSSD 2)