36Interlock function Valid (Manual reset)External device monitor function ValidAuxiliary output Can be usedThe device output is selected depending on the connecting state of the output polarity setting wire(shield). Incorrect wiring may cause the lockout state.* SymbolsSwitch S10 to +1.5V (source current 5mA or less): Emission halt, Open: EmissionK1, K2: External device (Forced guided relay or magnetic contactor)Notes: 1) The circuit diagram shown above is for 12-core cable to be used. For 8-core cable, red, yellow, gray, gray /black, sky-blue / white, sky-blue / black, there is no lead wire.2) For resetting, refer to “3-2 Interlock Function.”+ 24V DC±10%-K1K2Load*S1K1 K2(Shield) Output polarity setting wire(Blue) 0V(Brown) +V(Pale purple) Interlock setting input(Gray) Interference prevention +(Gray / Black) Interference prevention -(Red) Muting lamp output(Yellow) Override input(Yellow-green) External device monitor input(Brown) +V(Shield) Output polarity setting wire(Sky-bule / White) Muting input A(Sky-bule / Black) Muting input B(Gray / Black) Interference prevention -(Gray) Interference prevention +(Pink) Emission halt input / Reset input(Yellow-green / Black) Auxiliary output(Blue) 0V(Orange) Synchronization +(Orange / Black) Synchronization -(Orange) Synchronization +(Orange / Black) Synchronization -Gray cableGray cablewith black line (Black) Control output 1 (OSSD 1)(White) Control output 2 (OSSD 2)EmitterReceiver