-47-RESET SPOT Alarm SuspensionThis function disables activation of the alarm linkand instead enables recording of any alarm activat-ed in the alarm log.It is used to suspend the alarm link during camerasetup.1. Press the RESET and SPOT buttons simultaneouslyfor more than two seconds to suspend the alarm.The LED on the RESET button lights up.2. Press the RESET button again to reset the alarmsuspension.The LED on the RESET button goes off.OTHER FUNCTIONS Recording on the Time LapseVCRThe following selections are made on the SETUPMENU described previously.Refer to the Recording Mode on page 28 for moredetails.1. Check the selected recording mode (MODE 0 -MODE 9).MODE 0: Normal Mode (Real Time)MODE 1 - 9: Time Lapse Mode (Linear Mode)If MODE 9 is selected, check the picture (Spot orQuad) to be recorded on the VCR.2. Press the Record button of the VCR to begin record-ing.Notes:• To let the VCR display the VCR menu for setup,select MODE 0 in the REC MODE SETUP menuof the Multiplexer.• While recording with the camera switching pulse(MODE 9), quad recording will work properlywhen the selected recording interval is morethan 0.11 seconds (less than 9 fields/s).• While recording without the camera switchingpulse (MODE 1 - 8), quad recording is not avail-able.When using a VCR whose recording interval is 2or 3 fields, select 4 fields (minimum) for the RECMODE parameter.However the same picture may be recordedrepeatedly. Camera Switching Pulse LossDisplay• When loss of the camera switching pulse is detect-ed, “SW LOSS” will blink on the monitor screen.• The buzzer does not beep.• When the camera switching pulse is recovered, “SWLOSS” is cleared from the monitor.Notes:• When MODE 0 to MODE 8 is selected forrecording, or MULTI 2 OUT for REC OUT, “SWLOSS” is not displayed because of the way thesystem application works.• If “ALARM” or “CH PP LOSS” is displayed onthe monitor screen, “SW LOSS” is not displayedbecause alarm has priority.