60■ Sequence Setup (Spot Monitor)This item lets you program the live sequence pattern to berun on the Spot Monitor.Live sequence is a series of 16 steps assigned to the SpotMonitor. This sequence can be run on the MultiscreenMonitor by operating the buttons.● Live Sequence Pattern Setting1. Move the cursor to SPOT LIVE SEQUENCE SETUP inthe SEQUENCE SETUP menu by pressing the D or Cbutton, then press the SET button.The menu shown below appears on the monitor screen.2. Move the cursor to the step editing area by pressingthe A, B, D or C button.3. Select a camera number to be displayed for the CAMediting area by pressing the + or - button.1 - 16: Displays the image of the selected camera num-ber.--: Disables the display and will skip automatically.4. Move the cursor to the PRESET editing area by press-ing the B button, then select a preset position to bedisplayed by pressing the + or - button, if applica-ble.1 - 64: Selects a preset position of the assigned cam-era.--: No preset positionThe factory default setting is --.Note: To assign the parameters 1 - 64, the specifiedcombination cameras are equipped in the systemwith a PS•Data* mode.5. Move the cursor to SEC editing area by pressing the Bbutton, then select the desired dwell time by pressingthe + or - button.0S: The step will not be displayed on the monitor.1S - 30S: Selects the dwell time between 1 second and30 seconds.The factory default setting is 2S.● Group Multi Sequence SettingAs described before, the cameras are assigned to 4groups for recording with a programmed internal timer.This item lets you select the sequence pattern to be dis-played of each group on the Multiscreen Monitor.● Group Multi Sequence Pattern Setting1. Move the cursor to the GROUP SEQ MODE parameterin the SEQUENCE SETUP by pressing the D or C but-ton.2. Select either QUAD or MULTI GROUP display mode tobe run on the monitor by pressing the + or - button.MULTI GROUP: Camera images are displayed insequence with the minimum quantities of the seg-ment screen.QUAD: Camera images are displayed with a 4-segmentscreen in sequence.The factory default setting is QUAD.● Dwell Time Setting1. Move the cursor to the SEQ DWELL parameter in theSEQUENCE SETUP by pressing the D or C button.2. Select the desired dwell time for the group sequenceby pressing the + or - button.1S - 30S: Selects the dwell time between 1 second and30 seconds.The factory default setting is 2S.● Auto Skip SettingThis item lets you enable or disable the auto skip functionon the Multiscreen Monitor to skip any steps when no videosignal is present.1. Move the cursor to the AUTO SKIP parameter in theSEQUENCE SETUP by pressing the D or C button.2. Select either ON or OFF by pressing the + or - but-ton.ON: Enables the auto skip function on the MultiscreenMonitor.OFF: Disables the auto skip function on the MultiscreenMonitor.The factory default setting is ON.5-1-3 SPOT LIVE SEQUENCE SETUPPRE- PRE-STEP CAM SET SEC STEP CAM SET SEC1 1 -- 2S 9 9 -- 2S2 2 -- 2S 10 10 -- 2S3 3 -- 2S 11 11 -- 2S4 4 -- 2S 12 12 -- 2S5 5 -- 2S 13 13 -- 2S6 6 -- 2S 14 14 -- 2S7 7 -- 2S 15 15 -- 2S8 8 -- 2S 16 16 -- 2S