81Step 1Select the desired day of the week.→ The time table of the selected day of the week will bedisplayed.Step 2Configure each setting item.There are 2 setup pages. To move to another page, selectthe [k] or [l] button.[Copy the other program]To copy a time table set for another day of the week, selectthe day of the week to be copied, and select the [Copy] but-ton.■ New time table setupConfigure the settings of the following item for each timezone.[Start]Set the start time of the time zone.[End]Set the end time of the time zone.Note:• The time can be set in 1-minute increments.However, the end time should be at least 15 minuteslater than the start time.• It is impossible to set "23:46" or later for the start time.• Set "Start" and "End" in the 24-hour time display format.[Program]Select the desired program (PROG1 to 4).[Event]Select "On" or "Off" to determine whether or not to performevent actions at an event occurrence.[Alarm message]Select "On" or "Off" to determine whether or not to displaythe pop-up window that notify of an event occurrence with amessage on the screen of the PC.[FTP image transmission by alarm]Select "On" or "Off" to determine whether or not to transmitthe alarm image to the FTP server according to the settingsof "Image transmission by alarm" (+ page 96) on the"Server" page - the [FTP] tab.Assign a program after setting the time zone [Time table]Select the [Time table] tab on the "Schedule" page. (+ Page 60)A time table for program actions can be created for each day of the week, and programs can be assigned to each time table. Upto 6 time tables can be created for each day of the week.When a signal is supplied from the ALARM/CONTROL connector (external recording changeover, pin no. 24), the recorder willwork with the set timetable for "Ext." regardless of the days of the week.At the default, 0:00 to 24:00, PROG1 has been set for "Daily".