27 Sequence Setup (Spot Monitor)The described below let you program the sequence patternfor the Spot Monitor. Sequence Timing SettingThis item lets you select between internal and external con-trol for advancing the sequence on the Spot Monitor.1. Select either INT or EXT to advance the sequence byclicking the button.The item lets you select between internal and externalcontrol for advancing the sequence on the SpotMonitor.INT: Advances a sequence by the Dwell Time that wasprogrammed on the (SPOT) LIVE SEQ SETUP.EXT: Advances a sequence by the input from pin 5 ofthe ALARM port on then rear of the Disk Recorder.The factory default setting is INT.2. Select either ON or OFF to enable or disable the autoskip function by clicking the button.The item lets you enable or disable the auto skip func-tion on the Spot Monitor to skip any steps when novideo signal is present.ON: Enables the auto skip function on the Spot Monitor.OFF: Disables the auto skip function on the SpotMonitor.The factory default setting is ON.3. Click the [SET] button to execute the selections. Multi Live Sequence Setting(Multiscreen Monitor)There are three sequence patterns to run on theMultiscreen Monitor.The items shown below let you program the sequence torun on the Multiscreen Monitor.Multi Live Sequence is a series of 16 steps assigned to theMultiscreen Monitor.The sequence steps can be combined with four screensegments (quad) display.1. Click the MULTI LIVE SEQ SETUP in the underneath ofthe SEQUENCE SETUP window.The window shown in the figure will appear on the dis-play.2. Select a camera to be displayed in the CAM column forstep 1 by pressing the keyboard.1 - 16: Displays the image of the selected camera num-ber.4A - 4D: Displays the assigned images in quad.Refer to the QUAD PATTERN SETUP for settings.––: Disables display and will skip automatically.3. Select a preset position to be displayed in the PRESETcolumn for step 1 by pressing the keyboard, if applica-ble.01 - 64: Selects a preset position of the assigned cam-era.––: No preset positionThe factory default setting is ––.Note: To assign the parameters 1 - 64, the specifiedcombination cameras are equipped in the systemwith a PS.Data* mode.4. Select a dwell time in the SEC column for step 1 bypressing the keyboard.0S: The step will not be displayed on the monitor.1S - 30S: Selects a dwell time between 1 second and30 seconds.5. Repeat the above steps 2 to 4 to program the othersteps.6. When satisfied with all of the above steps, click the[SET] button to execute the selections.