Configuration Option TablesA-10 7976-A2-GB20-10August 1998Table A-4. Communication Port Options (3 of 3)Login Required (Terminal Use Only)Possible Settings: Enable, DisableDefault Setting: DisableSpecifies if an ID and password are required to access the asynchronous terminalinterface on the communication port. Login IDs are created with a password and accesslevel. Refer toCreating a Login in Chapter 7,Security.Enable – Login ID and password are required to access the asynchronous terminalinterface.Disable – No Login ID and password are required to access the asynchronous terminalinterface.Port Access Level (Terminal Use Only)Possible Settings: Administrator, OperatorDefault Setting: AdministratorSpecifies the highest level of access allowed when accessing an ATI session through aTelnet session.Administrator – This is the higher access level, permitting full control of theModel 7976 Termination Unit. Access level is determined by the Login ID. IfTelnet Login Required is disabled, the session access level is Administrator.Operator – This is the lower access level, permitting read-only access to status andconfiguration screens.Inactivity Timeout (Terminal Use Only)Possible Settings: Enable, DisableDefault Setting: DisableProvides automatic logoff of a Telnet session.Enable – The terminal session terminates automatically after the Disconnect Time.Disable – A terminal session will not be closed due to inactivity.Disconnect Time (Minutes) (Terminal Use Only)Possible Settings: 1 – 60Default Setting: 5Number of minutes of inactivity before the session terminates automatically. Timeout isbased on no keyboard activity. Disconnect Time (minutes) appears when Inactivity Timeout is enabled.1 to 60 – The Telnet session is closed after the selected number of minutes.