261001108-01-CMonitor (TouchMix-30 Pro only)The monitor output is most commonly used to feed a pair of monitor loudspeakers.To adjust Monitor level: Monitor Use the Master Rotary Encoder.The monitor pop-up includes the following controls:• Source Selector – Selects a signal for the Monitor output.» Aux 1 through 14 – The monitor output signal is derived form theselected Aux mix.» Main LR – The monitor output signal is derived from the Main L/Routput.» Cue – The monitor output follows the Cue selection.• In – Engages / bypasses the delay.• Delay – The delay is used to align the audio coming from a distant stagewith the near-field monitor signal heard at the mixer position. Digitalreadouts are in feet, milliseconds, and meters.Touch Close or push Monitor to close the pop-up.Monitor (TouchMix-16 only)Controls the output level for the Monitor CueTo adjust Monitor level: Monitor Use the Master Rotary Encoder.Monitor / Cue Level – Controls the level of the Cue signal on the Monitor outputs.NOTE!: By default, no audio signal is sent to the Monitor Outputs. To sendaudio channel signals (including Main LR) to the Monitor Outputs, enable the Cuebutton for the channels you want to listen to.Touch Close or push Monitor to close the pop-up.Solo In Place (SIP) (TouchMix-30 Pro only)When setting up a sound system, it can be very useful to mute all the inputs except for the one being worked on. This could be accomplished bymanually muting all the other channels but there’s a more convenient way.To set up Solo In Place: Menu Mixer Setup Solo in PlaceWhen Solo In Place is engaged, the input channels’ Cue buttons change color to light red and are labelled SIP. Touching a channel’s SIP button willmute all the other input channels and the SIP button turns solid green. Multiple inputs may be soloed. The Cue system functions normally for themixer’s outputs.IMPORTANT!: Solo In Place (SIP) is an extremely useful function for setup and troubleshooting but can be hazardous during a show.Be certain to disengage Solo In Place when setup is complete.-40-20-10-5U510Aux 1Aux 5Aux 9Aux 13Aux 2Aux 6Aux 10Aux 14Aux 3Aux 7Aux 11Main LRAux 4Aux 8Aux 12CueMonitorSourceDelayIn 0.00 feet0.00 ms0.00 mClose