C–Flash UpdateQLogic Adapter Flash Update — Windows ServerNE0154601-00 A C-5Flash Update ProcedureTo update the Windows Server 2003 and 2008 operating system (OS) Flash:1. On the Start menu, click Run. The Run dialog box opens.2. Type cmd in the Open: box, and then click the OK button.3. Go to the utils directory in the driver package provided.The following binaries must be in the same directory from where the Flashcommand will be executed:nxflash.exe[card type]-romimageThe release may contain multiple ROM images. The [card type] variablein the previous command refers to the exact ROM image. See the ReleaseNotes for more information on the ROM image types.Note that the nxflash utility and ROM image files must be in the samedirectory from where the nxflash command is executed.4. Type the following command, where n is the number of the port beingflashed:nxflash.exe -i “Local Area Connection n” --all (the quotationmarks are required)Writing the Flash takes a few minutes. Do not interrupt or reboot the systemduring this time.--pxe-off PXE This command disables PXE.--wol-on WOL This command enables wake on LAN.--wol-off WOL This command disables wake on LAN(default).-d name.xml Create XML This command creates an XML file that con-tains QLogic adapter/firmware information.For Windows Server, the XML file will be inthe current directory.-h--helpHelp This command displays the help menu.-v--versionVersion This command displays the version informa-tion.Table C-1. Flash Utility Commands — Windows Server (Continued)Command Definition Description