Chapter 7: Device Management134Trap Name DescriptionuserSessionTimeout A user with an active session has experienced asession termination due to timeout.vmImageConnected User attempted to mount either a device or imageon the target using Virtual Media. For every attempton device/image mapping (mounting) this event isgenerated.vmImageDisconnected User attempted to unmount a device or image onthe target using Virtual Media.Power Supply SetupThe Dominion KX II provides dual power supplies, and can automaticallydetect and provide notification regarding the status of these powersupplies. Use the Power Supply Setup page to specify whether you areusing one or both of the power supplies. Proper configuration ensuresthat the Dominion KX II sends the appropriate notifications should apower supply fail. For example, if power supply number one fails, thepower LED at the front of the unit will turn red.To enable automatic detection for the power supplies in use:1. Choose Device Settings > Power Supply Setup. The Power SupplySetup page opens.2. If you are plugging power input into power supply number one(left-most power supply at the back of the unit), then select thePowerln1 Auto Detect option.3. If you are plugging power input into power supply number two(right-most power supply at the back of the unit), then select thePowerln2 Auto Detect option.