27DECIMAL PLACE LOCATIONS11. DECIMAL SHIFTThe DECIMAL SHIFT feature is used to increase system accuracy at low application rates. Shiftingof the decimal point is done during the entry of METER CAL. After entering METER CAL mode,depress the decimal shift , enter the meter calibration constant number, and depress .The sequence to unshift the decimals while in METER CAL is to enter the meter calibration constantnumber and depress . The following table illustrates how shifting the decimal point canincrease system accuracy.US METRIC TURFUNSHIFT SHIFT UNSHIFT SHIFT UNSHIFT SHIFTRATE DISPLAY 000.0 00.00 0000 000.0 00.00 00.00RATE 1 CAL 000.0 00.00 0000 000.0 00.00 00.00RATE 2 CAL 000.0 00.00 0000 000.0 00.00 00.00TANK VOLUME 0000 000.0 0000 000.0 000.0 000.0TOTAL AREA 000.0 000.0 000.0 000.0 0000 0000TOTAL VOLUME 0000 000.0 0000 000.0 000.0 000.0FIELD AREA 000.0 000.0 000.0 000.0 0000 0000FIELD VOLUME 0000 000.0 0000 000.0 000.0 000.0VOL/MINUTE 0000 000.0 0000 000.0 000.0 000.0AREA/HOUR 000.0 000.0 000.0 000.0 0000 0000RATE +/- 000.0 00.00 0000 000.0 00.00 00.00LOW TANK LEVEL 0000 000.0 0000 000.0 000.0 000.0LOW VOL/MIN 0000 000.0 0000 000.0 000.0 000.0When entering RATE 1 CAL and RATE 2 CAL, remember that 2 GPA [20 lit/ha] is entered as 2.0 [20.0]when unshifted and 2.00 [20.00] when shifted.