43APPENDIX 7PROCEDURE TO RE-CALIBRATE FLOW METER1) Enter a METER CAL number of 10 [38] in the key labelled .2) Enter a TOTAL VOLUME of 0 in the key labelled .3) Switch OFF all booms.4) Remove a boom hose and place it into a calibrated 5 gallon [19 liter] container.5) Switch ON appropriate boom switch (for the hose that was just placed into the 5 gallon container)and the MASTER switch. Pump exactly 10 gallons [38 liters].6) Readout in TOTAL VOLUME is the new METER CAL number. This number should be within +/-3% of the calibration number stamped on the tag of the Flow Meter.7) Repeat this procedure several times to confirm accuracy. (Always "zero out" the TOTAL VOLUMEdisplay before retesting).NOTE: For greatest precision, set METER CAL to 100 and pump 100 gallons (378 liters)of water.8) To verify Flow Meter calibration, fill applicator tank with a predetermined amount of measured liquid(i.e. 250 gallons). DO NOT RELY ON GRADUATION NUMBERS MOLDED INTO APPLICATORTANK. Empty the applicator tank under normal operating conditions. If the number displayed underTOTAL VOLUME is different from the predetermined amount of measured liquid by more than +/- 3%, complete the following calculation:EXAMPLE:METER CAL = 720 [190]TOTAL VOLUME = 260 [984]Predetermined amount of measured liquid = 250 [946]Corrected METER CAL = METER CAL x TOTAL VOLUMEPredetermined amount of measured liquidENGLISH UNITS: METRIC UNITS:= 720 x 260 = 749 = [190] x [984] = [198]250 [946]Corrected METER CAL = 749 [198]9) Enter corrected METER CAL before resuming application.