194. VOLUME/MINUTE RATE FAULTDepress until DATA display flashes. A low limit flow rate may now be entered.If the actual volume per minute falls below this limit, the Control Valve stopsclosing, an alarm sounds, and the display flashes "-LL-". The low limit valueshould be determined with all booms ON. This value is automatically proportionalto the percentage of booms that are ON. (i.e. If the entered low limit is 4 andhalf the total boom length is shut off, the Console automatically reduces the lowlimit to 2).NOTE: Go to DATA MENU to silence alarm.5. VOLUME/AREA RATE ALARMConsole alarm sounds if the application rate is 30% or more away from thetarget application rate for more than 5 seconds.NOTE: Go to DATA MENU to silence alarm.7. AUTOMATIC RATE +/-This feature sets the increment at which flow is increased or decreasedin RATE 1 or RATE 2 operation. Enter rate change value by depressing keylabelled until DATA display flashes. To enter a value depress ,then the increment value, and .EXAMPLE: If rate is to change by "1.0":Enter a value of 1.0 for RATE +/-. When in RATE 1 or RATE 2, each timethe INC/DEC switch is positioned to INC the RATE CAL for that rate willincrease by "1.0". Likewise, when positioned to DEC the RATE CAL willdecrease by "1.0".6. LOW TANK FAULTThis feature will sound the alarm when the volume in the tank drops belowan entered value. The alarm will intermittently beep every 15 seconds andthe RATE display will flash "LEVL". The alarm will stop when a value equalto or greater than the LOW TANK ALARM is entered into VOL/TANK or the boomsare turned OFF. Entering "0" into LOW TANK ALARM disables it.To select LOW TANK ALARM depress until DATA display flashes. To entervalue depress ,then LOW TANK ALARM value, and .NOTE: Go to DATA MENU to silence alarm.