2112. DATA MENUThe following are brief descriptions of features available under the DATA MENUkey (some features are only available on consoles with serial interface port):DISPLAYRATE DATA FEATURE and DESCRIPTIONPrn bEGn CONSOLE DATA PRINTOUTSends data through serial port to attached optional printerto print field begin and field end pages (Serial interfaceconsole only).ALrn on AUDIBLE ALARMS ON/OFFTurns audible alarms ON or OFF for the following:1) Volume/Area Rate Alarm2) Volume/Minute Rate Fault3) Low Tank FaultdiSP on DISPLAY SMOOTHING ON/OFFTurns display smoothing ON or OFF. Selecting displaysmoothing ON means the RATE window displays target rate whenactual rate is within a percentage of target rate. The thirddigit of VALVE CAL determines this percentage.rATE on RATE CHANGE ALARM ON/OFFTurns rate change alarm ON or OFF. When rate change alarmis selected ON; alarm sounds 4 long beeps when the rate 1calibration number is changed via the serial port using avalid change request data string (Serial interface consoleonly).FILE 1 GPS FILE REFERENCEUsed only with Raven Grid Application System. See GridApplication System manual for more details (Serial inter-face console only).GPS InAC GPS OPTIONSUsed only with Raven Grid Application System. See GridApplication System manual for more details (Serial inter-face console only).FrEF 0 FIELD REFERENCEAllows user to enter up to a four-digit number to representa field. Field reference is included in field begin andfield end pages and the data logger time/date string (Serialinterface console only).