64 | City Series CV72EPVinstallation919-821 08.24.172CITY SERIES17. Reinstall pilot cap and pilot retainer clip.18. Prior to installing burner—adjust aerations settings - to 3/8" for LP. Re-install burner (see Step 11).19. Ensure the pilot light is in the correct orientation to the Burner. Recon-nect the gas and electrical supply to the appliance. Start the appliance.(see section on Lighting Instructions) Ensure that pilot and burner igni-tion is completed without delay. Check both your inlet and outlet pres-sures at full load. With a soapy solution, leak test the entire system.Verify both the correct flame and pilot appearance.20. See Gas Pipe Pressure Testing in manual.15. Remove pilot retainer clip with pliers and pull off the pilot cap to exposethe pilot orifice.16. Unscrew the pilot orifi ce with the Allen key; then replace with the LPGpilot orifi ce and the pilot cap, provided in the kit.Installer Notice:These instructions must be leftwith the appliance.Pilot retainer clip14. Remove burner orifice with a 3/8" wrench. Use another wrench to holdon to the elbow behind the orifice. Discard orifice. Reinstall new burnerorifi ce LPG stamped #47 and tighten.Burner OrificeLocation13. Loosen 8 screws in locations shown below (2 at front and 2 at rear)—slideburner to the left away from the orifice and lift out.12. Bend the arm of the aeration lever bracket up from 90° to straighten andrelease aeration lever (lever will come with the burner).Burner screw locationsSlide burner to the left and lift outCity SeriesNG SYSTEM DATAMin. Supply Pressure 11" WC (2.73kpa)Manifold Pressure - High 10" WC (2.49 kpa)Manifold Pressure - Low 6.4" WC (1.59 kpa)Orifi ce Size #47 DMSMaximum Input 45,500 Btu/h (13.33 kW)Minimum Input 36,000 Btu/h (10.55 kW)Altitude 0-4500 ft (0-1372m)AerationleverBracket