Regency City Series Owners & Installation Manual
Also see for CB40E-LP11: Manual
CV40E-11 City Series | 5safety decalThis is a copy of the label that accompanies Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is locatedon the front inside base of the unit, visible when the outer front panel is removed.NOTE: Regency ® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.Copy of Safety DecalFor the State of Massachusetts, installationand repair must be done by a plumber orgas fitter licensed in the Commonwealth ofMassachusetts.For the State of Massachusetts, flexible con-nectors shall not exceed 36 inches in length.For the State of Massachusetts, the appli-ances individual manual shut-off must be at-handle type valve.The State of Massachusetts requires theinstallation of a carbon monoxide alarm inaccordance with NFPA 720 and a CO alarmwith battery back up in the same room wherethe gas appliance is installed.Part #: 919-929aColour: Black on grey except what is indicated as being printed red.Size: (File at 100%) 9.18"W x 6.198"HMaterial:Oct. 15/18: Created draftNov. 05/18: New Serial #Nov 20/18: Added efficiencies as per R/DJan 23/19: Rev A - Remodeled decal + added ETL logo at the bottomDO NOT REMOVE THIS LABEL /NE PAS ENLEVER CETTE ÉTIQUETTE484484DOOR SEAL: Pleasecheck that the door isproperly sealedFPI Fireplace Products International Ltd. Delta, BC, CanadaMinimum Clearances to Combustibles /Dégagements minimaux par rapport aux matériaux combustiblesSerial No./ No de série919-929aMAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.Listed/Nom: VENTED GAS FIREPLACE HEATERS / APPAREIL DE CHAUFFAGE AU GAZ À ÉVACUATION.Certified to/Certifi :é ANSI Z21.88-2017 • CSA-2.33-2017CSA 2.17-2017Electrical supply / Alimentation électrique 115VAC, 1.5 A, 60Hz.Made in Canada/ Fabriqué au CanadaDuplicate S/N(See Instruction Manual for detailed instructions)(Voir manuel pour plus de détails)APPAREIL FONCTIONNANT AU GAZ PROPANEModèle CV40E-LP11/CB40E-LP11PROPANE GAS: Model: CV40E-LP11/CB40E-LP11NATURAL GAS: Model: CV40E-NG11/CB40E-NG11Minimum supply pressureManifold pressure - HighManifold pressure - LowOrifice sizeMaximum inputMinimum inputAltitudeAPPAREIL FONCTIONNANT AU GAZ NATURELModèle CV40E-NG11/CB40E-NG115.0" WC/C.E. (1.25 kPa)3.8" WC/C.E. (0.94 kPa)1.1" WC/C.E. (0.27 kPa)# 42 DMS28,500 Btu/h (8.33 kW)15,500 Btu/h (4.54 kW)0-4500 ft/pi (0-1372 m)11" WC/C.E. (2.73 kPa)10.5" WC/C.E. (2.62 kPa)2.9" WC/C.E. (0.72 kPa)# 53 DMS28,500 Btu/h (8.35kW)15,500 Btu/h (4.54 kW)0-4500 ft/pi (0-1372 m)Minimum supply pressureManifold pressure - HighManifold pressure - LowOrifice sizeMaximum inputMinimum inputAltitudeDEFABCSide Walls / Murs latérauxA 8.5” (216 mm)Ceiling / PlafondB 37-1/2” (953 mm)Min. Mantel Height /Hteur MinManteauC 9" (229 mm) with 12” mantelMax. Mantel Depth/Profondeur MaxManteauD 12” (305 mm)Alcove Width/Largeur AlcôveE 84" (1524 mm)Alcove Depth/Profondeur AlcôveF 36" (2134 mm)This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in theUnited States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational VehiclesThis appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited bylocal codes. See owner's manual for details. This appliance is supplied with a conversion kit.L'appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation National Fuel Gas Code ANSI Z223.1, ou CSA-B149.1 Natural Gas andPropane Installation Code en vigueur.L'appareil doit être installé conformément à la norme CAN/CSA-Z240, Série MM, Maisons mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Constructionand Safety Standard. Si ces normes ne sont pas applicables, veuillez vous référer à la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501CStandard for Recreational Vehicles.Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée (É.-U. seulement) ou mobile installée à demeure si les règlementsC #: 4001172For Use Only with Barrier CV40E - 1 sided (Part # 940-435/P) & CB40E 3 sided (Part # 940-438/P,940-439/P,940-440/P) Follow installation instructions.Utiliser uniquement avec l’écran CV40E -1 face (n°940-435/P) & CB40E - 3 faces (n°940-438/P,940-439/P,940-440/P) . Suivre les instructions d'installation.Pression d'alimentation minimalePression de sortie (manifold) - HautePression de sortie (manifold) - BasseTaille de l’orificeD bit calorifique maximaléD bit calorifique minimaléAltitudePression d'alimentation minimalePression de sortie (manifold) - HautePression de sortie (manifold) - BasseTaille de l’orificeD bit calorifique maximaléD bit calorifique minimaléAltitudeVENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUELS.NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.FOYER AU GAZ À ÉVACUATION -Part No. 946-556 Heatwave Kit may be used. Le système Heatwave (pièce n°946-556) peut être utilisé.Model/Modèle : CV40E-NG11 CV40E-LP11 CB40E-NG11 CB40E-LP11FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY À UTILISER AVEC LES PORTES VITRÉES HOMOLOGUÉES POUR L'APPAREILMin. 120in²Refer to Intertek's Directory of Building Products for detailed information.Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1Natural Gas / Gaz naturel 55.23%Propane Gas / Gaz propane 56.06%CANADIAN ENERGYPERFORMANCEVERIFIEDRENDEMENTÉNERGÉTIQUEVÉRIFIÉEP5011169Decal LocationRemove barrier glass from unit (refer to manual)lift out the outer liner base glass once the glasshas been removed the rating plate will be attachedto a small black chain as seen below.DO NOT REMOVE DECAL FROM UNIT |
Related manuals for Regency CB40E-LP11
Regency City Series Owners & Installation Manual
Regency City Series Owners & Installation Manual
Regency City Series Owners & Installation Manual
Regency City Series CB60E Series Owners & Installation Manual
Regency City CV60E Series Owners & Installation Manual
Regency City ACV40E Series Owners & Installation Manual
Regency City CP60E Owners & Installation Manual
Regency City CB50E Owners & Installation Manual
Regency City CST60E Owners & Installation Manual
Regency City CST50E Owners & Installation Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine