54 | CV40E-11 City SeriesinstallationOuter Safety Glass Panel (Barrier Glass) Installation / RemovalThe outer glass safety panel to be installed during the initial installation afterthe unit is in the final position.Note: The outer safety panel comes with plastic corners to protect these againstdamage. These should be kept in place until such time the outer safety panelsare installed. Ensure these are removed prior to operating the appliance. Keepthe plastic corners in a safe place if ever removing the outer panels for servicing.1. Carefully remove glass safety panels from packaging.3. Tilt the top of the glass panel inward and lift up and underneaththe upper front panel of the outside frame. Hook the glass panelonto the pins and also onto the two angle adjustment brackets lo-cated on the frame in two locations as shown in the diagram below.Note: The front frame upper panel is shown as transparent to betterillustrate the install (this area is not visible when installing glass).Press glass vacuum clamp in open position firmly onto surface of glass. Bringhandles together to close.Open ClosedNOTE: Inner glass panel shown in image - depicting proper handlingof glass.WARNING: GLASS HANDLINGWe recommend using the glass vacuum holders supplied by the manufac-turer. Lower the glass to rest in a safe place, this is to prevent damage to theglass edges. Extra care must be taken when removing/installing the glass.Breakage or damage to the edge of the glass which occurs as a result ofcareless handling will not be covered under warranty.• We recommend handling the glass with supplied vacuumclamps• When removing glass–prepare a soft, scratch resistantsurface to place the glass• Never clean or remove hot glassNote: The suction cups may leave a round film on the glasswhen used. Ensure that the glass is cleaned using a fireplaceglass cleaner prior to operating the appliance.Note: If the outer safety glass panel does not sit at 90º and angles too farinward or outward, remove the glass panel and adjust the screw ofthe panel angle bracket. Turn the panel angle bracket screw in 1/4increments—reinstall panel to check.Angle adjustment bracketsPins on body of unitPanel angle bracket—toadjust, turn screw:Clockwise = bring panel inCounter clockwise= bringpanel out2. Using the supplied vacuum clamps, lift the large front glass panel andposition it front and centre by manoeuvering up and underneath the frontof the unit frame.Note: safety glass panels must be installed to operate fireplaceTo watch the safety barrier glass installation video click here.