4 Regency ® E21-2 Gas Fireplace InsertSAFETY LABELThis is a copy of the label that accompanieseach Regency ® Gas Insert. We have printeda copy of the contents here for your review.The safety label is located on the front insidebase of the unit visible when the bottom louveris open.Note: Regency ® units are constantly beingimproved. Check the label on the unitand if there is a difference, the labelon the unit is the correct one.Please note that with the additionof thermostat control and outsidecombustion air supply, this unit isapproved for bedroom installations.Listed: VENTED GAS FIREPLACE HEATERTested to: ANSI Z21.88b-2003/CSA-2.33b-2003, CGA 2.17-M91Gas fired appliance for use at high altitude.Certified for/Certifee pour: CANADA and U.S.A. Report No. 476-1428-00 (DEC. 2000)Model/Modele:DO NOT REMOVE THIS LABEL/ NE PAS ENLEVER CETTE ÉTIQUETTE296Serial No./No de Serie918-488Minimum Clearances to Combustibles/Degagement Minimum Des MateriauxCombustibles:Side of unit to wall /Cote:A 9"/229mmTop of unit tomantle / Au dessus:B 14"/355mmMADE IN CANADA / FABRIQUE AU CANADAFPI Fireplace Products International Ltd., Delta, B.C., CanadaFIREPLACE INSERT: E21-NG2 E21-LP2 APPAREIL FONCTIONNANT CONCU POURNatural Gas (Naturel Gaz) Propane ETRE INSERE DANS UN FOYERMinimum supply pressure 5.0" WC/C.E. (1.25 kPa) 12.0" WC/C.E. (2.99 kPa) Pression d’alimentation minimumManifold pressure high 3.8" WC/C.E. (0.95 kPa) 11.0" WC/C.E. (2.74 kPa) Pression tublure d'échappement élevéeManifold pressure low 1.1" WC/C.E. (0.27 kPa) 2.9" WC/C.E. (0.72 kPa) Pression tublure d'échappement basseAltitude 0-2000 ft. 2000 - 4500 ft. 0-4500 ft. L'altitude(0 - 610m) (610 - 1372m) (0-1372m)Orifice size 43 DMS 44 DMS 54 DMS Grandeur de l’injecteurMaximum input 23,500 Btu/h 22,000 Btu/h 22,500 Btu/h Debit calorifique maximumMinimum input 11,750 Btu/h 11,000 Btu/h 11,250 Btu/h Debit calorifique minimumDuplicate Serial No.NOT FOR USE WITH SOLID FUEL. NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.For installation into a vented non-combustiblefireplace, listed factory built fireplace. This ventedgas fireplace heater is not for use with air filters.Ne peut etre installe que dans un foyer noncombustible muni d'un event. Ne pas utiliser defiltre à air avec ce foyer au gaz à évacuation.WARNING: This fireplace has been converted for usewith a gas fireplace insert only and cannot be used forburning wood or solid fuels unless all original partshave been replaced, and the fireplace re-approved bythe authority having jurisdiction.E L E C T R I C A L S U P P LY / A L I M E N T A T I O NELECTRIQUE:115V60HZ less than/Moins de 2 AMP.E21-NG2 E21-LP2296For the State of Massachusetts, installationand repair must be done by a plumber orgasfitter licensed in the Commonwealth ofMassachusetts.For the State of Massachusetts, flexibleconnectors shall not exceed 36 inches inlength.For the State of Massachusetts, the appli-ances individual manual shut-off must be at-handle type valve.The State of Massachusetts requires theinstallation of a carbon monoxide alarm inaccordance with NFPA 720 and a CO alarmwith battery back up in the same room wherethe gas appliance is installed.