32 | Regency ® P33-10 Zero Clearance Direct Vent Gas Fireplace|32installationCONVERSION FROM NG TO LPFor P33-10 Using SIT 829 NOVA Gas ValveTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!1 10.17.14919-466Each Kit contains one LPConversion KitLP Conversion Kit Contains:Qty. Part # Description1 904-575 Burner Orifice #551 910-582 Stepper Motor1 918-590 Decal "Converted toLPG"1 908-528 Red "LPG" label1 904-529 5/32" Allen Key1 910-037 LPG Injector(Pilot Orifice)1 919-466 Instruction SheetConversion from NG to LPGusing SIT 829 NOVA Gas ValveRemove the 2 screws, push BurnerAssembly to the left and lift out.Installation of the LPGConversion Kit:1. Shut off the gas and electrical supply.2. a) Remove the faceplate if installed.b) Remove the safety screen and glassdoor- see manual for detailed instruc-tions.c) Remove the logs, embers, and brickpanels (if installed).d) Remove the 2 screws holding theBurner Assembly to the firebox base.Push the Burner Assembly to the leftand lift out.4. Unscrew the pilot orifice with the Allenkey and replace with the LP pilot orificein the kit and replace pilot cap.3. Remove pilot clip below pilot cap.5. Remove burner orifice with a 1/2"wrench and discard. Use another wrenchto hold on to the elbow behindthe orifice.Burner Orifice6. Reinstall new burner orifice LPGstamped #55 and tighten.ClipPilot CapP33THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTERIF IN DOUBT DO NOT DO THIS CONVERSION!!7. Remove NG stepper motor by removing3 screws in locations shown below–re-place with LP stepper motor, secure inplace with 3 screws.Remove NG Stepper motor andreplace with LP Stepper motorInstaller Notice:These instructions must be leftwith the appliance.8. Check for gas leaks with a proper soapysolution or leak detector.9. Check for proper spark between theignitor and pilot cap. Refer to "LightingProcedure" section of the manual forlighting sequence.10. Check pilot flames. Correct flame patternhas 3 strong blue flames. Adjustmentcan be made by turning the slottedscrew at the top right corner of thevalve. Refer to "Maintenance Instruc-tions" section of the manual for correctflame patterns.11. Check inlet and outlet pressures. Referto "Gas Pipe Pressure Testing" sectionof the manual.12. Reverse Steps 3 to 1.13. Attach the label "This unit has beenconverted to LP" near or on top of theserial # decal.14. Replace yellow "NG" label with red "LP"label.15. Check operation of flame control.16. Check for proper flame appearance andglow on logs.