Regency ® P33-10 Zero Clearance Direct Vent Gas Fireplace | 5|5safety decalSAFETY LABELThis is a copy of the label that accompanies each P33-10 Zero Clearance Direct Vent Gas Fireplace. We haveprinted a copy of the contents here for your review. The safety label is located on the front inside base of theunit, visible when the bottom louver is open.NOTE: Regency ® units are constantly being improved. Check the label on the unit and if there is a difference,the label on the unit is the correct one.For the State of Massachusetts, installationand repair must be done by a plumber orgasfitter licensed in the Commonwealth ofMassachusetts.For the State of Massachusetts, flexibleconnectors shall not exceed 36 inches inlength.For the State of Massachusetts, the appli-ances individual manual shut-off must be at-handle type valve.The State of Massachusetts requires theinstallation of a carbon monoxide alarm inaccordance with NFPA 720 and a CO alarmwith battery back up in the same room wherethe gas appliance is installed.DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE421Minimum supply pressureManifold pressure highManifold pressure lowOrifice sizeMinimum inputMaximum inputAltitudeNATURAL GAS: Model P33-NG10PROPANE: Model P33-LP10Minimum supply pressureManifold pressure highManifold pressure lowOrifice sizeMinimum inputMaximum inputAltitudeDOOR SEAL: Please check thatthe door is properly sealedFPI Fireplace Products International Ltd.Delta, BC, CanadaMinimum Clearances to CombustiblesDegagement Minimum De Materiaux Combustibles0" Clearance tocombustibles from:Top,sides, bottom and rear of unitMantel Clearances from Top:(A) Min. " ( mm)10 254Side Wall Clearance from SideFacingB) 7.5"(191mm)Alcove ClearancesMax. Depth 36" (914mm)Min. Width 48" (1219mm),Min. Height 59“ (1499mm)(See Instruction Manual forDetailed Instructions)Serial No./ No de serie919-3935" WC (1.25 kPa)3 " WC (0. kPa).5 871. " WC (0. kPa)6 39# 44 DMS1 00 Btu/h ( kW)4,0 4.12 00 Btu/h ( kW)0.0 5.860- ft/pi (0- m)4500 1372APPAREIL FONCTIONNANT AU NATURAL GASCONCU POUR ETRE POELE: Modéle P33-NG10Pression d'allimentation minimumPression a la tubulure d' chappement lev eé é éPression a la tubulure d' chappement basseéGrandeur de l'injecteurD bit Califorique minimum selonéD bit Caliorfique maximum selonél'altitudeAPPAREIL FONCTIONNANT AU PROPANECONCU POUR ETRE POELE: Modéle P33-LP10Pression d'allimentation minimumPression a la tubulure d' chappement lev eé é éPression a la tubulure d' chappement basseéGrandeur de l'injecteurD bit Califorique minimum selonéD bit Caliorfique maximum selonél'altitudeVENTING: Use listed Simpson Dura-Vent GS System or Regency Direct Vent System. Only for direct discharge without duct connection. This appliancemust be installed in accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the current ANSI Z223.1 in theUSA or the current CAN 1-B149 in Canada. For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance withthe manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standardfor Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile HomeStandard in Canada.VENTILATION : Système de GS de Dura-conduit de Simpson énuméré par utilisation ou circuit de mise à l'air libre direct de Regency.Seulement pour la décharge directe sans connexion de conduit. Cet appareil \ndoit être installé selon les instructions d'installation du fabricantet avec des codes locaux éventuels ; sinon, suivez la norme ANSI actuelle Z223.1 dans \nLes Etats-Unis ou le courant PEUVENT 1-B149 dansle Canada. Pour l'installation à la maison manufacturée : Cet appareil direct de circuit de mise à l'air libre doit être installé selon\n les instructionsd'installation du fabricant et le titre à la maison manufacturé 24 CFR de construction et de norme de sécurité, la partie 3280, ou la norme actuelle \npourdes critères de sécurité incendie pour les installations, les sites, et les Communautés à la maison manufacturés ANSI/NFPA 501A, et avec la caravanerésidentielle de CAN/CSA Z240 MH \nNorme dans le Canada.For Use Only with Barrier 439-005 Follow installation instructions. Utiliser uniquement avec l’écran ( n ° 439-005) Suivre les instructions d'installation.(Part # )This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.Fan (Part # 43 -917) Option: HeatWave Kit # 946-5568MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.Model/Modele:P33-NG10Model/Modele:P33-LP10Made in Canada/Fabrique au CanadaDuplicate S/NMinimum clearance of VentTerminal to Outside Corner &Inside Corner: 6"/150mmHorizontal Terminations requirethe use of the AstroCapTM(Part # 946-523)11" WC (2.74 kPa)1 " WC (2. kPa)0 496.4 1.59" WC ( kPa)# 5 DMS51 ,500 Btu/h ( kW)4 4.2418 0 5.28, 00 Btu/h ( kW)0-4500 ft/pi (0-1372 m)4001172421NOT FOR USE WITH SOLID FUELS.NE PAS UTILISER AVEC DESCOMBUSTIBLES SOLIDE.Listed: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATIONCANADA and U.S.A.Certified for/Certifi e pour:éCertified to: CAN/CGA-2.17-M91(R2009)ANSI Z21.88-20 CSA 2.33-2014 & 14Tested to:CeilingB B30"WallAAB BELECTRICAL SUPPLY/ALIMENTATION ELECTRIQUE:115V_60HZ less than/moins de 2 AMP