Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace32gram 2) and then lift the entire assembly out(diagram 3).10) Undo the pilot tube from the valve with a7/16" wrench.REMOVING VALVE1) Shut off the gas supply.2) Remove the louvers (and bay door if it is on).3) Open the flush door and remove the door.4) Remove the logs.5) Remove the burner/grate assembly by re-moving the two Phillips head screws andthen lift the burner assembly out.Diagram 1: Remove the left and right screwsand then lift out the burner/grate assembly.6) Remove the rear log stand by removing the2 screws.7) Disconnect the inlet gas line. See diagram2.8) Disconnect the 2 TP wires and the 2 THwires from the valve.9) Remove the 10 Phillips head screws secur-ing the valve tray assembly in place (dia-Diagram 2: Rear Log Stand & Valve Tray Assemblyscrews Valve Tray AssemblyRear Log StandscrewsMAINTENANCEINSTALLING VALVE1) Attach the valve to the valve bracket withthe 4 (m5x8 metric) screws provided.2) Reconnect the "gas out" flare fitting withan 11/16" wrench.3) Reconnect the "gas out" flare nut with a 13/16" wrench.4) Install piezo ignitor push button assemblyand reconnect wire.5) Reconnect the quick drop out thermocou-ple nut with a 9mm wrench.6) Reconnect the pilot tube nut with a 7/16"wrench.7) Scrape off the old gasket from the floor ofthe firebox and from the valve tray assem-bly.8) Install a new gasket and reinstall the valvetray assembly.Note: Failure to install a new gasketmay severely affect the applianceperformance.9) Reinstall the 10 hold down screws.10) Hook up the 2 TP and 2 TH wires to theappropriate connections on the valve.11) Reinstall the front log stand.12) Install Burner/grate assembly.13) Hook up the gas line and check for gasleaks with a soap and water solution or agas leak detector. (Do not use open flamefor leak testing.)14) Fire up the unit temporarily.15) Check the manifold pressure.16) Reinstall the logs and brick panels asneeded.17) Close the door and replace the louvers.18) Fire up the unit again and check for properflame appearance and glow on logs.11) Undo the quick drop out thermocouple nuton the valve with a 9mm (metric) wrench.12) Remove the Piezo igniter wire and pushbutton assembly.13) Undo the "gas out" flare nut with a 13/16"wrench.14) Undo the "gas out" flare fitting with an 11/16" wrench.15) Remove the 4 Phillips head screws from thesides of the valve bracket and removevalve.Hint: If you are using black pipe, ensure thatthere is a union by the valve, otherwise removalwill be almost impossible.Diagram 3: Lift out Valve Tray Assembly