FPI P36-4 Zero Clearance Direct Vent Gas Fireplace 43INSTALLATIONREMOTE CONTROL(OPTIONAL)Use the FPI Remote Control Kit approved forthis unit. Use of other systems may void yourwarranty.The remote control kit comes with a hand heldtransmitter, a receiver and a wall mountingplate.1) Choose a convenient location on the wallto install the receiver and the receptaclebox (protection from extreme heat is veryimportant). Run wires from the fireplaceto that location. Use the Thermostat WireTable.2) Connect the two wires to the gas valve. Seediagram below.CAUTIONDo not connect millivoltremote control wiresto 120V wire.3) Install 3 AAA alkaline batteries in transmitterand 4 AA alkaline batteries in the receiver.Install the receiver and its cover in the wall.Switch the remote receiver to "remote"mode. The remote control is now ready foroperation.WALL SWITCH(OPTIONAL)1) Run the wire through the right or left sideinlet opening. Be careful not to damagewire.Note: We recommend a maximum of 15'of wire but if you wish to go with alonger run, use the Thermostat WireTable.2) Connect the wire to the wall switch and installinto the receptacle box. See the "AlternateWiring Diagram for Wall Switch" section forwiring diagrams.CAUTIONDo not connect millivoltwall switch wireto 120V wire.14 GA.16 GA.18 GA.20 GA.22 GA.50 Ft.32 Ft.20 Ft.12 Ft.9 Ft.Recommended Maximum Lead Length(Two-Wire) When Using WallThermostat (CP-2 System)Wire Size Max. LengthThermostat Wire TableWALL THERMOSTAT(OPTIONAL)A wall thermostat may be installed if desired,connect the wires as per the wiring diagram.Use the table below to determine the maximumwire length.Note: Preferable if the thermostat isinstalled on an interior wall.FPI offers an optional programmable thermostatbut any 250-750 millivolt rated non-anticipatortype thermostat that is CSA, ULC or UL approvedmay be used.CAUTIONDo not connect millivoltwall thermostat wiresto 120V wire.