FPI P36-4 Zero Clearance Direct Vent Gas Fireplace 4949INSTALLATIONOPERATING INSTRUCTIONSMAINTENANCEINSTRUCTIONS1) Always turn off the gas valve before cleaning.For relighting, refer to lighting instructions.Keep the burner and control compartmentclean by brushing and vacuuming at leastonce a year. When cleaning the logs, use asoft clean paint brush as the logs are fragileand easily damaged.2) Clean appliance and door with a dampcloth (never when unit is hot). Never usean abrasive cleaner. The glass should becleaned with a gas fireplace glass cleaner.The glass should be cleaned when itstarts looking cloudy.3) The heater is finished in a heat resistantpaint and should only be refinished withheat resistant paint. FPI uses StoveBrightPaint - Metallic Black #6309.4) Make a periodic check of burner for properposition and condition. Visually check theflame of the burner periodically, making surethe flames are steady; not lifting or floating.If there is a problem, call a qualified serviceperson.5) The appliance and venting system must beinspected before use, and at least annually,by a qualified field service person, to ensurethat the flow of combustion and ventilationair is not obstructed.Note: Never operate the appliance withoutthe glass properly secured in place.6) Do not use this appliance if any part has beenunder water. Immediately call a qualifiedservice technician to inspect the applianceand to replace nay part of the control systemand any gas control which has been underwater.7) Verify operation after servicing.GENERAL VENTMAINTENANCEConduct an inspection of the venting systemsemi-annually. Recommended areas to inspectas follows:1) Check the Venting System for corrosion inareas that are exposed to the elements.These will appear as rust spots orstreaks, and in extreme cases, holes.These components should be replacedimmediately.2) Remove the Cap, and shine a flashlightdown the Vent. Remove any bird nests, orother foreign material.COPY OF THE LIGHTING PLATE INSTRUCTIONSOFFa