MWS_55_e.indb Page 16Manual MWS 55 / MWS 88 / MWS 10 and Sensors 55geändert am 26.10.2017 von DOREINHARDT System- und Messelectronic GmbHFax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.deto table of contents3.5 Sensor AccuracyTemperature: ± 0.3 °CHumidity: ± 2.0 % (at 10°C..35°C)Pressure: ± 0.8 hPa (at 0°C..50°C), ±2 hPa below 0°CRain/precipitation: ± 0.2 mmWind direction: ± 5° (at 5°C..50°C), hysteresis < 8°Start speed: < 0.5m/s (at 5°C..50°C)Wind speed: ± 2.5 km/h (at 5°C..50°C)Start speed: < 0.5 m/s (at 5°C..50°C)Global radiation: +/- 40W (at 25°C)UV-radiation: +/- 10%Light intensity: +/- 6%Additional analogue inputs: ± 3mV (at 0°C..50°C)3.5.1 Measuring RangesTemperature: from -40 ° to + 60 °, resolution 0.01 °Relative humidity: from 0 to 100 % resolution 0.03 %Dewpoint: from -40 ° to + 60 °, resolution 0.01 °Barometric pressure: from 950 hPa to 1050 hPa in 0.01 hPa resolutionAbsolute pressure: from 300 hPa to 1100hPa in 0.01 hPa resolutionPrecipitation: from 0 to 5000 mm with 0.1mm resolutionWind direction: 0 to 360 °, resolution 0.025 °Wind speed: in km/h from 0 to 200 km/h with 0.01 km/h resolutionGlobal radiaion from 0 to 1300 W/m² (Spectral range 0.3..2.8μm)Light intensity: from 0 to 220000 Lux (Spectral range: human eye response)UV-radiation: from 0 to 50000 mW/m² (Spectral range 320..395nm)Additional inputs: 0- 4.095 VSupply 4-28 V, 150 mA at 18 VDC, standard equipmentDimensionsSize: Outer diameter 90 mm, height 240 mm (MWS 55)Size: Outer diameter 240 mm, height 215 mm (MWS 10)Weight: app. 1.05 kg (MWS 55)Weight: app. 2.9 kg (MWS 10)Weight: app. 800 g (10m ready made cable with PSU)The housing must be mounted centrally on a 1" pipe.Standard cabling is 10 m - longer cabling on request.