MWS_55_e.indb Page 52Manual MWS 55 / MWS 88 / MWS 10 and Sensors 55geändert am 26.10.2017 von DOREINHARDT System- und Messelectronic GmbHFax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.deto table of contents6.3 RS422/RS485 interfaceWith RS422 data are sent immediately after applying power to the station.With RS485 the station can receive data after applying power but does not send any data. Theoutput is tri state. Data only will be sent on request with the correct address.Initalization and memory check with RS485 are performed as well but without sending any datafor the output is disabled (tri state).While initializing after power up the weather station doesn't respond to any commands for app.10 seconds.For controlling the weather station with RS485 the address of the weather station must be addedafter the ! or ? command, otherwise the unit won't respond to any command.The default address with RS485 is 1.The command for reading the current data set therefore is ?1U for example contrary to ?U withall the other interface versions.