English970DISPLAY Description2.12. Allows resetting the statistical data.Reset3./ 4.SNACK 1/ SNACK 2…3.1./ 4.1. It allows manual testing of the photoelectric cell system operation. The machine emits abeep each time the photoelectric cell system detects an object.Photocell test…3.2./ 4.2. It allows forcing the alignment of all the motors of the machine. If the alignment is carriedout successfully, the pending errors are removed and the motor is activated for dispensing.Motor alignment…3.3./ 4.3. It allows forcing the alignment only of the motors of the machine where an error was detected. If the alignment iscarried out successfully, the pending errors are removed and the motor is activated for dispensing. This procedurewill remove all the photoelectric cell pending errors.Auto alignment…3.4./ 4.4. Shows recorded temperatures for the product tray for the last 24 hours. Values arerecorded every 10 minutes and saved with the time of detection.Temperature log…LOG TABLEExx WHAT ==> xx code error/warning alarmaabb WHERE ==> if Myy = spiral motor yyaabb WHERE ==> if Syy = yy instant product dispensingaabb WHERE ==> if Lyy = yy instant product rinsingaabb WHERE ==> if C — = coffee brewingaabb WHERE ==> if aabb = hexadecimal codesdd MMM WHEN ==> day in figures, month in string (3 letters)hh:mm WHEN ==> hour:minutesii error index in LOGNN number of errors in LOG