English18fig. 11A1234 5B157 - MAINTENANCE7.1 ForewordDangerBefore any servicing and/or cleaning, disconnect the ma-chine by way of main switch (ref. 10, fig. 1) and multi-poleswitch (or disconnect the plug) and await machine cooling.- The components that cannot be dismantled and the machineitself, have to be cleaned, unless differently specified, withcold or lukewarm water only, using non abrasive sponges anddamp cloths.- Do not use direct water sprays.- All parts to be cleaned are easily accessible and do not re-quire the use of tools.- Regular maintenance and cleaning will preserve the machineand maintain its efficiency for a longer period as well as con-forming to health and hygiene norms.- The machine automatically signals when the maintenance and/or descaling interventions are due; the exact number of dis-pensing instances is visible by the mechanical counter or onthe machine display. No intervention of the Maintenance tech-nician may result in machine locking.DangerIn case of operation troubles, normally signalled on display,immediately switch the machine off, disconnect the powerthrough a multi-pole switch or by disconnecting the plug andcontact the nearest SERVICE CENTRE.7.2 Cleaning of machineDangerNever clean the machine when it is in “STANDBY”status.Cleaning must be carried out daily and before any long deadtime, in order to avoid the formation of deposits in containers,trays and dispensers.All removable machine components that have to be cleaned canbe washed and rinsed in running water.Clean machine covers, panels and commands with soft and drycloths, or slightly dampened by cold or lukewarm water.ImportantNever wash machine components in the dishwasher.- Assemble the cup heating plate (ref. 4, fig. 11) by insertingthe electrical connector into the electronic board properly, thefitting into the drain tube (ref. B, fig. 11), and by connectingthe earth cable.- Manually rotate the studs (ref. A, fig. 11) so as to place themilling horizontally.- Assemble one of the side panels (or ref. 1, fig. 11 or ref. 5,fig. 11).ImportantFirstly slide in the bottom pins in their frame slots, then pressdirectly on the studs until hearing the locking springs snap.- Position the glass (ref. 2, fig. 11) in the slot of the lateral panelalready assembled.- Assemble the other side panel.- Insert the drip tray into place (ref. 15, fig. 11).- Switch machine on.6.17 Setting out of operationeDangerOperation falling within the competence of the Maintenancetechnician.When the machine is put out of operation, disconnect both waterand electrical mains; empty all trays, boilers and pipes and cleanthe whole machine properly (see “7.2 Machine cleaning”).In case of scrapping, the various materials used in manufacturingwill have to be separated and individually disposed of, accordingto each Country regulations in force.