70(change setpoint temperature).• If LED diode of the Network Status is flashing, pair the wiring centre withthe system in accordance to the manual instruction and pair thermostatwith wiring centre.7.ErrXX-07 Thermostat lost contact with the TRVhead.• Check TRV head batteries.• Send the heating signal from thermostat and check if the TRVhead is working.• If the LED diode on the TRV head is flashing, repeat the pairingprocedure with thermostat according to the manual instructions.8. ErrXX-08Thermostat has lost connection withthe RX10RF receiver (RX1 mode).• Is the RX10RF receiver plugged to the power supply and the topLED diode is red? The Auto/Manual switch has to be set to AUTOposition.• Force identification process from the coordinator/gateway sideand check if the devices are within the network.• Send the heating signal from thermostat• If the top LED diode is flashing, perform the pairing procedureaccording to the RX10RF manual instruction.9. ErrXX-09Thermostat has lost connection withthe RX10RF receiver (RX2 mode).• Is the RX10RF receiver plugged to the power supply and the topLED diode is red? The Auto/Manual switch has to be set to AUTOposition.• Force identification process from the coordinator/gateway sideand check if the devices are within the network.• Send the heating signal from thermostat• If the top LED diode is flashing, perform the pairing procedureaccording to the RX10RF manual instruction.11-18.ErrXX-11XX-18Wiring centre has lost connectionwith thermostat of the given zone:e.g. 11 = with zone 1; 12 = with thezone 2 etc. Error is displayed on allthermostats.• Check the thermostat power supply.• Send the heating signal from thermostat.• If necessary, reinstall the thermostat.19.ErrXX-19Wiring centre has lost connectionwith the CO10RF coordinator/UGE600internet gateway.Error is displayed on all thermostats.• Is the wiring centre turned ON and Status Network LED diodesolid?• Force identification process from the coordinator/gateway sideand check if wiring centre is within the network.• If LED diode of the Network Status is flashing, pair the wiringcentre with the system in accordance to the manual instruction andpair all thermostats with wiring centre.20.ErrXX-20Wiring centre has lost connectionwith the RX10RF receiver operating inRX1 mode.Error is displayed on all thermostats.• Is the wiring centre turned on? Status Network LED diode shouldbe solid.• Force identification process from the coordinator/gateway sideand check if devices are within the network.• If the LED diode of the AUTO/MANUAL receiver switch is flashing,follow the RX10RF manual instruction for pairing.ERRORCODEDISPLAYDESCRIPTION ERROR DESCRIPTION TROUBLESHOOTING