16Product SpecificationsItems SpecificationModel RF23HT**Components for Freezer CompressorModel MKV190CL2B/E01Starting type BLDCOil Charge FREOL α - 15cEvaporator Freezer SPLIT FIN TYPERefrigerator SPLIT FIN TYPECondenser Forced and Natural Convection TypeDryer Molecular shieve XH-9Capillary tube (Dia x Length) R:0.032" (0.082mm x 3500mm)Refrigerant R134aRoom Temperature SensorComponentsFreezer Model TemperatureSelection On(°F) Off(°F)THERMISTOR(F-SENSOR)-8°F (-23°C) -5°F (-21°C) -11°F (-24°C)-0°F (-18°C) 3°F (-16°C) -3°F (-19°C)5°F (-15°C) 8°F (-12°C) 2°F (-17°C)Refrigerator Model TemperatureSelection On(°F) Off(°F)THERMISTOR(R-SENSOR)502AT34°F (1°C) 36°F (2°C) 32°F (0°C)37°F (3°C) 39°F (4°C) 35°F (2°C)44°F (7°C) 46°F (8°C) 42°F (6°C)Defrost Related ComponentsDefrost Cycle First Defrost Cycle (Concurrent defrost of Fand R) 6hr ±10minDefrost Cycle (FRE) 12~30hr (vary according to the conditions used)Defrost Cycle (REF) 6~15hr (vary according to the conditions used)Pause time 12 ±1minDefrostSensor F Defrost-Sensor Model THERMISTOR (502AT)SPEC 5.0 ㏀ at 77℉(25℃)R Defrost-Sensor Model THERMISTOR (502AT)SPEC 5.0 ㏀ at 77℉(25℃)BimetalF Bimetal-thermoProtectorRated AC 250V 3AOperatingtemperature Off : 140℉(60℃) / On : 104℉(40℃)R Bimetal-thermoProtectorRated AC 250V 3AOperatingtemperature Off : 140°F (60°C) / On : 104°F (40°C)