WEC8500/8050 Operation Manual Version 5.2Samsung Electronics America page 377 of 533Configuration using Web UIIn the menu bar of <WEC Main window>, select <Administrator> and then select the<SNMP> <Community> menu in the sub-menus. When you click the <Add> button inthe Community window, the community creation window is displayed. When you enter aconfiguration value and click the <Apply> button, the configuration is applied.Figure 196. Adding SNMP community10.1.2 SNMP TrapAll the alarms of the APC system are basically transmitted to outside through the SNMPtrap. Therefore, to receive a system alarm from an external management server, the serveraddress must be registered as a trap target. The trap supports v1/v2.Configuration using CLITo add a SNMP trap target, execute the command as follows:1) Go to configure mode of CLI.WEC8500# configure terminalWEC8500/configure#2) Add a SNMP trap target. snmp trap [TRAP_VERSION] [COMMUNITY_NAME] [IP_VERSION][IP_ADDRESS] [PORT_NUMBER]Parameter DescriptionTRAP_VERSION Trap version (v1/v2)COMMUNITY_NAME Name of a community to be transmittedIP_VERSION IP address type (v4/v6)IP_ADDRESS IP address to which a trap will be transmittedPORT_NUMBER Port number to which a trap will be transmitted (default: 162)3) To check the added trap target, use the ‘show snmp trap’ command.