PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications23/728.5.7 CF_DLINE CommandCommand “CF_DLINE_%1”[CR]%1“0100”~”nnnn” --- Directly select Display Line setting value“nnnn” shows maximum value, it is current Total Line value – VerticalPosition value“UP” -------------- Current Display Line setting value + 1“DN” -------------- Current Display Line setting value – 1DetailsSet Display Line value of PC signalThe value set by this command will not be saved to projector. Therefore, whenturning into Standby status or ALL is OFF, the value returns to original setting.This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.5.8 CF_PCSTORE CommandCommand “CF_PCSTORE_%1”[CR]%1“MODE1” ------ Store current PC Adjust status to Mode1“MODE2” ------ Store current PC Adjust status to Mode2“MODE3” ------ Store current PC Adjust status to Mode3“MODE4” ------ Store current PC Adjust status to Mode4“MODE5” ------ Store current PC Adjust status to Mode5“MODE6” ------ Store current PC Adjust status to Mode6“MODE7” ------ Store current PC Adjust status to Mode7“MODE8” ------ Store current PC Adjust status to Mode8“MODE9” ------ Store current PC Adjust status to Mode9“MODE10” ---- Store current PC Adjust status to Mode10DetailsStore current PC Adjust status (each parameter status such as Total dots) toMode1~Mode10. This command operates the same as storing to Mode1-Mode10in PC Adjust MENU.This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.5.9 CF_PCMODEFREE CommandCommand “CF_PCMODEFREE_%1”[CR]%1“MODE1” ------ Set Mode1 to Free status“MODE2” ------ Set Mode2 to Free status“MODE3” ------ Set Mode3 to Free status“MODE4” ------ Set Mode4 to Free status“MODE5” ------ Set Mode5 to Free status“MODE6” ------ Set Mode6 to Free status“MODE7” ------ Set Mode7 to Free status“MODE8” ------ Set Mode8 to Free status“MODE9” ------ Set Mode9 to Free status“MODE10” ---- Set Mode10 to Free statusDetailsDelete the registered data in Mode1-Mode5 and turns it to Free status.This command operates the same as turning Mode1-Mode5 to Free in PC AdjustMenu.This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]