PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications42/728.10.27 CF_FANMODE CommandCommand “CF_FANMODE_%1”[CR]%1 “L1” ---------------------------- Set Fan Mode to L1“L2” ---------------------------- Set Fan Mode to L2DetailsSwitch Fan ModeWhen L1 is selected, fan noise after POWER OFF is louder.When L2 is selected, fan noise after POWER OFF becomes quiet. However fanrotates longer than L1.The status set by this command is stored in EEPROM and its setting is effectiveeven after ALL is OFF.This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.28 CF_FANCONTROL CommandCommand “CF_FANCONTROL_%1”[CR]%1“OFF” ---------------------------- Set Fan control to Off“ON1” ---------------------------- Set Fan control to On1“ON2” ---------------------------- Set Fan control to On2DetailsSet Fan control setting.The status set by this command is stored in EEPROM and its setting is effectiveeven after ALL is OFF.This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.29 CF_DELAYCTRL CommandCommand “CF_DELAYCTRL_%1”[CR]%1 “ON” --------------------------- Set Video delay control On“OFF” -------------------------- Set Video delay control OffDetailsSet Video delay control.The status set by this command is stored in EEPROM and its setting is effectiveeven after ALL is OFF.This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.10.30 CF_FILTIMER CommandCommand “CF_FILTIMER_%1”[CR]%1“2000” -------------------- Set 2000 hours“3000” -------------------- Set 3000 hours“4000” -------------------- Set 4000 hours“OFF” --------------------- No warning display“UP” --------------------- Switch Filter timer forward(Off →2000 → 3000 → 4000 → Off)“DN” --------------------- Switch Filter timer backward(Off → 4000 → 3000 → 2000→ Off)Details Set timer of Filter warning display.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]