PLC-WL2500 / WL2501/ WL2503 Expand Serial Command Functional Specifications65/729.11.14 CR_P-MANE CommandCommand “CR_P-MANE”[CR]Details Get Power management setting statusAcceptable “000_%a”[CR]%a“OFF” -------------------------- Power Management is OFF“READY” ---------------------- Power Management is Ready“SHUTDOWN” ---- Power Management is set to Shut Down modeResponseUnacceptable “Error code”[CR]9.11.15 CR_P-MANETIME CommandCommand “CR_P-MANETIME”[CR]Details Get time to start Power ManagementAcceptable “000_%a”[CR]%a “001”~”030” -----------------------1 minute to 30 minutesResponseUnacceptable “Error code”[CR]9.11.16 CR_ON-STA CommandCommand “CR_ON-STA”[CR]Details Get Direct on setting statusAcceptable “000_%a”[CR]%a “ON” ------------------------- Direct on is active“OFF” ------------------------ Direct on is inactiveResponseUnacceptable “Error code”[CR]9.11.17 CR_PTIMEMODE CommandCommand “CR_PTIMEMODE”[CR]Details Get operation mode of P-timer.Acceptable “000_%a”[CR]%a “COUNTUP” ---------------- Count up is selected“COUNTDN” ---------------- Count down is selected.ResponseUnacceptable “Error code”[CR]9.11.18 CR_PTIMER CommandCommand “CR_PTIMER”[CR]Details Get current status of P-timerAcceptable “000_%a”[CR]%a“ON” ------------------------ P-timer is in execution“STOP” --------------------- P-timer is paused“OFF” ----------------------- P-timer is inactiveResponseUnacceptable “Error code”[CR]