-47-Electrical AdjustmentsGroup/Item Item Name Function Initial range Note6 Not used -Plc-xd2600Group253 Fan tem error Setting (Memorized) Normal Ceiling HiLand-Normal HiLand-Ceiling0 Temp A Warning (High) 45 45 44 44 -1 Temp B Warning (High) 55 54 54 54 -2 Temp C Warning (High) 59 59 58 58 - Temp B-A Warning(High) 100 100 100 100 -4 Temp C-A Warning(High) 100 100 100 100 -5 Temp A Warning (Normal) Temp. A to judge the Temp Error atNormal (Room) 45 45 44 44 0-1006 Temp B Warning (Normal) Temp. B to judge the Temp Error atNormal (Panel) 55 54 5 5 0-1007 Temp C Warning (Normal) Temp. C to judge the Temp Error atNormal (Lamp) 58 58 57 57 0-1008 Temp B-A Warning (Normal) Temp. B-A to judge the Temp Error atNormal (Clogging Det.) 100 100 100 100 0-1009 Temp C-A Warning(Normal) Temp. C-A to judge the Temp Error atNormal (Clogging Det.) 100 100 100 100 0-10010 Temp A Warning (Eco) Temp. A to judge the Temp Error at Eco(Room) 44 44 4 4 0-10011 Temp B Warning (Eco) Temp. B to judge the Temp Error atEco(Panel) 54 5 52 52 0-10012 Temp C Warning (Eco) Temp. C to judge the Temp Error atEco(Panel) 57 56 55 55 0-1001 Temp B-A Warning (Eco) Temp. B-A to judge the Temp Error atNormal (Clogging Det.) 100 100 100 100 0-10014 Temp C-A Warning (Eco) Temp. C-A to judge the Temp Error atNormal (Clogging Det.) 100 100 100 100 0-10015 Temp A Warning Offset(Temp)Offset of Temp Error (Temp.)Error Setting Value is increased XC atthe below condition* Standby* Right to turn on the lamp*Right to change the Lamp mode5 0-10016 Temp B Warning Offset(Temp) 5 0-10017 Temp C Warning Offset(Temp) 5 0-10018 Temp B-A Warning Offset(Temp) 0 0-10019 Temp C-A Warning Offset(Temp) 0 0-10020 Temp A Warning Offset(Time)Offset of Temp Error (Minutes)Error Setting Value is increased X min-ute at the below condition* Standby* Right to turn on the lamp*Right to change the Lamp mode 0-10021 Temp B Warning Offset(Time) 0-10022 Temp C Warning Offset(Time) 0-1002 Temp B-A Warning Offset(Time) 0-10024 Temp C-A Warning Offset(Time) 0-100Plc-xd2600Group254 Fan control range Setting (temp./Voltage) Normal Ceiling HiLand-Normal HiLand-Ceiling0 High Fan Control Min Temp 2 1 2 -1 High Fan Control Max Temp 41 41 8 8 -2 High Fan1 Min 78 80 98 100 - High Fan1 Max 15 15 15 15 -4 High Fan2 Min 75 85 100 110 -5 High Fan2 Max 90 95 125 10 -6 High Fan Min 75 80 100 105 -7 High Fan Max 100 105 110 115 -10 Normal Fan Control Min Temp Temp Senser Control Start/End Tem.pat Normal 2 2 20-10011 Normal Fan Control MaxTemp 40 40 8 8 20-10012 Normal Fan1 MinFan voltage value at Normal (unit: 0.1V)68 75 95 100 0-2551 Normal Fan1 Max 15 15 15 15 0-25514 Normal Fan2 Min 7 85 100 11 0-25515 Normal Fan2 Max 96 101 124 129 0-25516 Normal Fan Min 75 80 100 105 0-25517 Normal Fan Max 15 15 15 15 0-25520 Eco Fan Control Min Temp Temp Senser Control Start/End Tem.pat Eco2 2 2 1 20-10021 Eco Fan Control Max Temp 40 9 8 7 20-10022 Eco Fan1 MinFan voltage value at Eco (unit: 0.1V)52 60 75 80 0-2552 Eco Fan1 Max 120 120 125 125 0-25524 Eco Fan2 Min 45 45 60 60 0-255