-49-Electrical AdjustmentsGroup/Item Item Name Function Initial range Note1 Fan2 Initial Volt Fan Start Voltage(0.1V) 55 0-2552 Fan Initial Volt 55 0-2554 Fan1 Cooling Speed Fan Voltage at Power Off (0.1V) 10 0-2555 Fan2 Cooling Speed 10 0-2556 Fan Cooling Speed 10 0-2558 Cooling Time L1 Cooling Time stting at Fan Mode L1 (x0 sec)1: 0, : 90, 15: 450 sec. 2 1-159 Cooling Time L2 Cooling Time stting at Fan Mode L2 (x0 sec)1: 0, : 90, 15: 450 sec. 1-1510 Temp Error Cooling Time Cooling Time setting at Temp Erro (x0 sec) 1-1511 OnStart Cooling Start Thresh-old 8 0-10012 After shutdown cooling Cooling after shutdown (0: No, 1: Yes) 1 0-1Group256 Fan/lamp Voltage dimmer Setting0 Lamp Vlotage - -1 Lamp Vol Threshold 0 0-902 Fan 1 Speed Gain 10 0-255 Fan 2 Speed Gain 10 0-2554 Fan Speed Gain 10 0-255Group257 Fan dimmer Setting0 Dimmer Average ChechPeriodDimmer Average measurement Time(0:10sec. 1:0sec. 2:60 sec. 90:sec...10:0sec.) 0 0-101 Dimmer Average Dimmer Average Value (Read only) -2 Last Voltage Difference - Voltage Difference Goal -Group258 Fan Network Ic temperature rising resolve0 Standby Cooling Check Cycle 51 Standby Cooling Start Threshold 402 Standby Cooling Enable 1Group260 Auto calibration(common)*Auto calibration0 Execute Calibration 0 0 - 1 Executes Auto-Calibration whenchangiing the Value (PC White100%)1 Loop Count Maximum Execution Times (OFFSET->GAIN) 10 1 - 02 Auto Status Result of Auto-Calibration (LastMemory) 0 0 / 1 / 9 0: OK, 1: Adjusting,9: Error *ReadOnly AutoWait Wait Value for each setting 1 1 - 204 CHECK -Tolelance Torelance of OFFSET 2 1 - 255Group261 Auto calibration (rGB)0 OFFSET AREA H START Black Level Acquiring Area H-StartPosition 975 0 - 10001 OFFSET AREA V START Black Level Acquiring Area V-StartPosition 500 0 - 10002 GAIN AREA H START White Level Acquiring Area H-StartPosition 25 0 - 1000 GAIN AREA V START White Level Acquiring Area V-StartPosition 500 0 - 10004 Image AREA H WIDTH Black/White Level Acquiring Area 1 0 - 40955 Image AREA V HIGHT Black/White Level Acquiring AreaHeight 9 0 - 40956 OFFSET target Target Value of Black Level Adj. 0 - 1277 OFFSET torelance Torelance of Black Level Adj. 1 1 - 1278 GAIN target Target Value of White Level Adj. 28 0 - 2559 GAIN torelance Torelance of White Level Adj. 1 1-255Group262 Auto calibration (cVBS/SVIdeo)0 Y Image Area Start X Y Acquiring Area H-Start Position 20 0-10001 Y Image Area Start Y Y Acquiring Area V-Start Position 200 0-10002 Cb Imange Area Start X Cb Acquiring Area H-Start Position 500 0-1000 Cb Imange Area Start Y Cb Acquiring Area V-Start Position 200 0-1000