PLC-XTC50AL Expand Serial Command Functional Specifications34/768.8 Lamp Command8.8.1 CF_LAMPMODE CommandCommand “CF_LAMPMODE_%1” [CR]%1“AUTO1” ------------- Set lamp status to Auto1 mode“AUTO2” ------------- Set lamp status to Auto2 mode“HIGH” --------------- Set lamp status to High mode“NORMAL” ---------- Set Lamp status to Normal mode“ECO1” --------------- Set Lamp status to Eco1 mode“ECO2” --------------- Set Lamp status to Eco2 mode“UP” ------------------ Select lamp control forward direction“DN” ----------------- Select lamp control backward directionDetailsSelect Lamp control (Available only in the normal Power ON status)The value set by this command is stored in EEPROM and the setting remainseffective after the power is turned to ALL OFF status.Response Acceptable “000” [CR]Unacceptable “Error Code” [CR]8.8.2 CF_LAMPCONTRL CommandCommand “CF_LAMPCONTROL_%1” [CR]%1“LAMP1” --------------------------- Set lamp mode to Lamp1“LAMP2” --------------------------- Set lamp mode to Lamp2“CHANGE”------------------------- Set lamp mode to Lamp1/2DetailsSelect Lamp mode. (Valid only when in the normal Power ON status.)The value set by this command is stored in EEPROM and the setting remainseffective after the power is turned to ALL OFF status.Response Acceptable “000” [CR]Unacceptable “Error Code” [CR]8.8.3 CF_LAMPLIFECONTRL CommandCommand “CF_LAMPLIFECONTROL_%1” [CR]%1 “MODE1” --------------------------- Set lamp life control to Mode1“MODE2” --------------------------- Set lamp life control to Mode2DetailsSelect Lamp life control (Valid only when in the normal Power ON status.)The value set by this command is stored in EEPROM and the setting remainseffective after the power is turned to ALL OFF status.Response Acceptable “000” [CR]Unacceptable “Error Code” [CR]8.8.4 CF_LAMPCHGTIM CommandCommand “CF_LAMPCHGTIM_%1” [CR]%1 “ON” --------------------------- Set Timer to On“OFF” -------------------------- Set Timer to OffDetailsSelect Timer for Lamp1/2 of Lamp mode.(Valid only when in the normal Power ON status.)*When Lamp mode is not set to Lamp1/2, error code “101” is returned.Response Acceptable “000” [CR]Unacceptable “Error Code” [CR]