PLC-XTC50AL Expand Serial Command Functional Specifications50/769.5 PC Adjust Status Read Command9.5.1 CR_FSYNC CommandCommand “CR_FSYNC” [CR]Details Get value of Fine SyncResponseAcceptable “000_%1” [CR]%1 “0000 – 0031”Unacceptable“Error Code” [CR] --- When command is not available in the givencondition (such as being selected input)“?” [CR] --- When unknown command is received9.5.2 CR_TDOTS CommandCommand “CR_TDOTS” [CR]Details Get value of Total DotsResponseAcceptable “000_%1” [CR]%1“mmmm” – “nnnn”(mmmm = Display area H + Position H)(nnnn = Maximum value less than 140 MHz of Dot Clock)Unacceptable“Error Code” [CR] ------------------------ When command is notavailable in the given condition (such as being selected input“?” [CR] ------------------- When unknown command is received9.5.3 CR_CLPPHASE CommandCommand “CR_CLPPHASE” [CR]Details Get value of Clamp Phase valueResponseAcceptable “000_%1” [CR]%1 “0001”~“nnnn”(“nnnn” depends on input signal)Unacceptable “Error Code” [CR]9.5.4 CR_H-POS CommandCommand “CR_H-POS” [CR]Details Get value of Horizontal PositionResponseAcceptable “000_%1” [CR]%1 “0000 – nnnn”(nnnn = Total Dots – Display area H)Unacceptable“Error Code” [CR] ------ When command is not available in thegiven condition (such as being selected input“?” [CR] ------------------- When unknown command is received